background image

8

Customer Support: 1-866-409-4581

PRE-OPERATION 
CHECKLIST 

Package Contents 

 

Model:  200CR 

Package contents: 

(1) Motor/Pump 

(1) Owner's Manual 

(2) Air Filters 

(4) Motor Mounts 

(1) Elbow (attached) 

 

Inspect for Damage 

Before using this product, inspect all parts for damage. 

Do not use this product if any damage is found. If damaged, 
return to dealer where item was purchased from.

 

Save Packaging 

IMPORTANT: Save all outside packaging in case you ever need 
to return the product for service or repair. 

 

 

Location 

 

Use on Flat Surface 

For proper operation, this product must be placed on a flat 
surface with an incline no greater than 15 degrees

 

 

Maintain a Clear Area 

It is very important that the motor/pump is positioned so that there 
is adequate airflow around the product. There must be at least 2 
feet of obstacle-free space surrounding the motor/pump. 

 

Use in Areas with Clean Air 

The motor/pump should not be used in areas where dust or 
particulates are in the air.  

This will cause damage to the motor/pump and impair proper 
operation.  

IMPORTANT:

 Always use the air filter, properly installed. 

Use caution to minimize risk of fire or explosion.

It is normal for the air compressor motor and 
pressure switch to produce sparks while operating. If 
sparks come in contact with vapors from gasoline or 
solvents, they may ignite and cause a fire or 
explosion.

Abrasive tools such as grinders, drills and other 
tools are capable of making sparks that can ignite 
flammable materials.

Always operate the air compressor a safe distance 
away from flammable items. Use in well-ventilated 
areas.

Never exceed the maximum rated pressure.

FIRE

WARNING

EXPLOSION

Dust or dust-like particulates caused by 
power-sanding, sawing, grinding, drilling or any 
other construction-like activities can contain 
contaminants that are harmful to breathe.

Always use your air compressor in a well-ventilated 
and clean area.

Never breathe the air that comes directly out of the 
air compressor or air hose. This air is not suitable for 
breathing.

Always wear approved safety equipment. When 
performing dust-creating activities, securely wear 
properly-fit face masks or respirators.

If you feel ill from breathing while operating your air 
compressor, stop and seek medical attention 
immediately.

WARNING

RISK TO BREATHING

Summary of Contents for 200CR

Page 1: ...RA QUIET OIL FREE AIR COMPRESSOR MOTOR PUMP OWNER S MANUAL CALIFORNIA AIR TOOLS 200CR 2 0 HP 110 VOLTS 60 HERTZ 6 00 CFM 40 PSI 5 00 CFM 90 PSI WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 45...

Page 2: ...____________________________10 Daily Operation________________________________10 MAINTENANCE _________________________________11 Changing the Air Filter__________________________11 Cleaning __________...

Page 3: ...Department Phone 1 866 409 4581 Online WWW CALIFORNIAAIRTOOLS COM Please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate P...

Page 4: ...compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable...

Page 5: ...ever make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints f...

Page 6: ...provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please c...

Page 7: ...7 Customer Support 1 866 409 4581...

Page 8: ...Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks...

Page 9: ...se a dedicated 110v 60hz 15 amp power supply Max 14 gauge 100ft extension cord Min 3000 Watt Running Generator WIRING MOTOR PUMP Wiring Instructions Black White Wires hot To Power Supply Green Wire To...

Page 10: ...n the power switch to the ON position 7 Do not use continously running for more than 8 hours of continuous running at 90 PSI and 12 hours at 40 PSI Shutting down the compressor 1 Turn the power switch...

Page 11: ...e solvent Do not use flammable liquids such as gasoline or alcohol Always keep parts clean from dirt and dust for better performance Use a blow gun to blow out any dust or debris inside the motor STOR...

Page 12: ...ut Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the moto...

Page 13: ...osts Thermal Overload Protector 125 PSI Maximum Pressure Ports 1 2 NPT Output Elbow 3 8 NPT 110v 60 hz Low Amp Draw 14 Amps Power Requirements Dedicated 15 amp outlet 3000 Watt running Generator Exten...

Page 14: ...ghts and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expre...

Page 15: ...ermined at the sole discretion of California Air Tools Inc Registration Warranty registration with California Air Tools Inc is required on all products You can mail the enclosed registration form or r...

Reviews: