AIR COMPRESSOR

MAINTeNANCe

draining the air tank

The frequency at which you should drain the air tank and air dryer

depends on the environmental conditions and the amount of

operating time logged. daily draining is recommended to not

damage the air compressor motor, dryer, tank and components.

1.

Place the air compressor above a container capable of holding

water. A pan with a dry towel would be advised.

Locate the drain valve at the bottom of the air tank.

2.

Without compressed air in the air tank, slowly turn the drain valve

knob to the forward (open) or straight down position.

The water in the air tank will drain out. 

3.

After all of the accumulated water has drained out, turn the drain

valve knob to the closed or left position in order to avoid leakage.

draining the air dryer

1.

At the bottom of the air drying column is a drain hole with a drain

tube attached.

Attach the other end of the drain tube to a container capable of

holding water. This tube will let the water from the air dryer drain.

2.

Remove waste container and empty.

changing the air filter

The air filters are designed to reduce noise and help prevent

particulates in the air from entering and damaging the air

compressor.
After being used for a period of time, the air filter will become

clogged. This will reduce the air intake capabilities of the air

compressor, reducing performance. Therefore, the air filter must be

replaced regularly.

1.

Open the lid of the air filter and remove the old air filter element.

2.

Replace with a new air filter element and close the lid.

testing for leaks

Make sure all connections are tight. do not overtighten.
A small leak in any hose or pipe connection will reduce the air

compressor's performance.
To test for small leaks, spray a small amount of soapy water on the

area suspected of leaking. If the soap bubbles, replace the broken

part.

cleaning

Clean items with a soft brush, or wipe with a moistened cloth using

a biodegradable solvent.
do not use flammable liquids such as gasoline or alcohol. Always

keep parts clean from dirt and dust for better performance.

air drying column - desiccant

After 4000 hours of use the Activated Alumina desiccant needs to

be replaced.
unscrew the air drying column bottom cap.
Remove the old desiccant (disguard) and add new desiccant.

STORAge

before storing for a prolonged period of time:

1.

Turn off the power supply.

2.

disconnect the power cord from the power supply.

3.

Pull the relief valve and release all the pressure from the air tank.

4.

Clean the air compressor to remove all dirt and dust.

5.

Cover the air compressor with a cover to protect the unit from

dust and moisture.

6.

do not stack or store any items on top of or around the air

compressor. damage could occur.

Summary of Contents for 10020DCAD

Page 1: ...ULTRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 10020DCAD WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581...

Page 2: ...enance _________________________________10 draining the air tank air dryer_________________10 changing the air filter__________________________10 testing for leaks ______________________________10 cle...

Page 3: ...OLS COM please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate Part number or numbers shown in the parts list section of t...

Page 4: ...the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are c...

Page 5: ...hments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder...

Page 6: ...6 Customer Support 1 866 409 4581 AIR COMPRESSOR...

Page 7: ...t there is adequate airflow around the machine There must be at least 2 feet of obstacle free space surrounding and above the air compressor use in areas with clean air For proper operation and to max...

Page 8: ...duty cord that is no more than 25 feet long and at least 14 gauge use only a 3 wire extension cord that has a 3 blade grounding plug OPeRATINg The AIR COMPReSSOR Save this manual for future reference...

Page 9: ...ing operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only plac...

Page 10: ...air filter will become clogged This will reduce the air intake capabilities of the air compressor reducing performance Therefore the air filter must be replaced regularly 1 Open the lid of the air fi...

Page 11: ...s not start and makes a humming noise Capacitor is burned out Replace starter capacitor The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage correspond...

Page 12: ...rth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gau...

Page 13: ...cific legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclu...

Page 14: ...ded by California Air Tools Inc 7 Normal wear 8 The use of accessories or attachments not recommended by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined a...

Page 15: ...tion date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number...

Reviews: