background image

11

Customer Support: 1-866-409-4581

AIR COMPRESSOR

test run

before using the air compressor for the first time.

Complete a test run as follows:

1.

Turn the power switch to the OFF position.

Plug the power supply cord into a power supply socket.

Start the air compressor by turning the power switch to the ON

position.

The pressure gauge reading will slowly rise as pressure

increases inside the air tank.

When the gauge reading reaches  120 PSI - 125 PSI, the

pressure switch will automatically turn the power off.

This indicates the compressor is working normally. 

2.

daily operation

Starting the compressor:

1.

Turn the power switch to the OFF position.

2.

Attach the air hose to the 1/4” quick connect coupler

3.

Close the drain valve.  

4.  have air filters attached

5.

Plug the power supply cord into a power supply socket.

6.

Turn the power switch to the ON position.

7.

Let the motor run and tank fill until motor turns off.

8.  

To regulate the air flow. 

While the air compressor is running, turn “On” your tool and 
turn the regulator knob to the right increasing the pressure. 
Turn the pressure up until the desired pressure is reached.

9.  

Operate air tool normally. 

Shutting down the compressor:

1.

Turn the power switch to the OFF position.

2.

unplug the power supply cord.

3.

Reduce the pressure in the air tank through the air supply

hose.

Air compressor surfaces become hot during 
operation.

DO NOT touch hot surfaces, because they can cause 
severe burns.

Do not touch the air compressor’s cylinder head. 
During operation, the cooling fins of the cylinder 
head and delivery pipe become hot.

Allow the air compressor to cool before touching it.

DO NOT place a storage cover on the unit during 
operation. Only place a cover on the air compressor 
after it has thoroughly cooled down.

FIRE

HOT SURFACE

WARNING

Flying objects can cause injury to the eyes, head and 
other parts of the body.

Air-powered equipment and power tools are capable 
of propelling items (metal chips, fasteners and 
particulates) at high speed into the air and could 
result in injury.

Always wear approved head and eye protection.

Never point the air stream at any part of your body, 
or at another person or animal.

When operating the air compressor, make sure all 
other people and animals maintain a safe distance.

Do not move the air compressor when the air tank is 
under pressure. 

Never use the air hoses to pull or move the air 
compressor.

Keep the air compressor on a flat surface.

WARNING

FLYING OBJECTS

note: 

If the Air Compressor is not working properly, the

pressure gauge will indicate that there is a decrease in

pressure in the air tank. If there is an air leak from the

compressor the pressure in the air tank decreases, the

pressure switch resets and the motor automatically turns

back on.
If you detect an air leakage, turn the power switch to the

Off position, release the air from the tank by pulling on

the safety valve. unplug the power supply cord and contact

Customer Support for Assistance.

Turn the power switch to the Off position, unplug the power

supply cord and release the air in the  tank by pulling on the

safety valve. At this point proceed to the next step (daily

operations).

Summary of Contents for 10020C-22050

Page 1: ...TRA QUIET OIL FREE AIR COMPRESSOR OwnER S MAnUAL CALIFORnIA AIR TOOLS 10020C 22050 2 0 HP 6 40 CFM 40 PSI 5 30 CFM 90 PSI 10 0 gALLOn STEEL TAnk WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 4581 ...

Page 2: ..._________________12 draining the air tank ___________________________12 changing the air filter__________________________12 testing for Leaks ______________________________12 pressure Switch _______________________________12 cleaning _____________________________________12 Storage______________________________________12 troubLeShootIng ____________________________13 SpecIfIcatIonS_________________...

Page 3: ...e grounding plug is able to result in a risk of electric shock When repair or replacement of the in a risk of electric shock When repair or replacement of the cord or plug is required do not connect the grounding wire cord or plug is required do not connect the grounding wire to either flat terminal The wire with insulation having an to either flat terminal The wire with insulation having an outer...

Page 4: ... the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable of propelling items metal chips fasteners and particulates at high speed into the air and could result in injury Always wear approved head and eye protection Never point the air stream at any ...

Page 5: ...chments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints for a discharge line WARNING EXPLOSION Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If spar...

Page 6: ...se labels provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact California Air Tools Customer Service department at 1 866 409 4581 for replacements PROduCT LAbeL a b c d e f g h ...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR ...

Page 8: ...ack of the air compressor Screw the air filters into the motor head ports Install the Wheel kit 1 Slide bolt 51 through Wheel 50 2 Slide the washer 49 onto bolt 51 3 Slide the bolt 51 through the wheel support hole located on the front bottom of the air compressor tank 4 Attached the Washer 49 and Nut 48 to the bolt 51and tighten firmly 5 Repeat steps 1 4 to assemble the other wheel 6 Slide bolt 8...

Page 9: ...t or particulates are in the air This will damage the motor and impair proper operation Important Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks come in contact with vapors from gasoline or solvents they may ignite and cause a fire or explosion A...

Page 10: ...f damage before connecting Ensure that all cords are free of damage before connecting to the power supply to the power supply Ensure that you have a sufficient electrical supply for Ensure that you have a sufficient electrical supply for supporting the requirements of the motor supporting the requirements of the motor Improper installation of the grounding plug is able to result Improper installat...

Page 11: ... cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the air compressor to cool before touching it DO NOT place a storage cover on the unit during operation Only place a cover on the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered ...

Page 12: ...ter then remove the air filter element 2 To clean the element blow off or brush off the dirt and dust 3 If clogged replace with a new air filter testing for Leaks Make sure all connections are tight do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leaking ...

Page 13: ...windings are burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the motor Check that the main voltage corresponds to the air compressor specifications An extension cord that is too thin or too long can cause a voltage drop use heavy duty extension cor...

Page 14: ...arth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gauge Regulator Pressure gauge Ball valve Filter Drain valve Air intake Check valve Solenoid valve Compressor Tank ...

Page 15: ...fic legal rights and you may also have other rights which may vary from state to state disclaimer of other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expressly in lieu of any and all other warranties including without limitation any implied warranties of merchantability or fitness for a particular purpose or any other implied warranties that...

Page 16: ... by California Air Tools Inc 9 Acts of god The application of these exclusions will be determined at the sole discretion of California Air Tools Inc registration Warranty registration with California Air Tools Inc is required on all products you can mail the enclosed registration form or register on line how to Videos California Air Tools provides hOW TO VIdeOS on our website WWW CALIFORNIAAIRTOOL...

Page 17: ...ation date of Purchase _____________________________________________________________ MM dd yyyy Model Number ______________________________________________________________________________ Serial Number ___________________________________________________________ Found on name plate Purchased Location __________________________________________________________________________ Purchase Price _________...

Reviews: