possible to connect nearly all worldwide available single phase mains. Please refer to chapter
Specifications
for more detailed informations.
This chapter describes how to install and start-up the sat-nms ACU19V. It is a step-by-step
description without detailed description. If you need more detailed description for e.g. some
parameter settings, please refer to chapter
5 Operation
, all of the parameters are described
here.
Before you start, please first read the
Safety Instructions
chapter. It contains some important
recommendations to prevent damage from the ACU.
Then, we strongly recommend to do a first setup of the ACU on a lab desk before installing it at
it's final location. This is mainly for the following reason:
To setup the ACU's IP parameters, the PC used for configuring and the ACU must either be
connected to the same Ethernet hub or must be connected directly with a crossover cable. The
initialization program does not work through routers or intelligent network switches.
Hence, the typical sequence of tasks when putting an sat-nms ACU19V into operation is as
follows:
1. Read the chapter
2 Safety Instructions
.
2. Set the ACU's
4.3.1 IP address
.
3.
4.1 Mechanically mount
the ACU19V.
4.
4.2 Connect the ACU
to the antenna (position encoders, motor driver interface). Finally
connect the mains power supply and the Ethernet network.
5. Start up the system and set the parameters as described below.
6. As last step enable the drive interface and start them up as described below.
Before you can operate the sat-nms ACU19V, you need to set the ACU's IP address. There is a
special configuration program on the documentation CD shipping with the ACU for this purpose.
We recommend to configure the ACU's TCP/IP settings before you install the sat-nms ACU19V at
it's final place. To configure the ACU, the following equipment is required:
The sat-nms ACU19V itself.
Mains power at connector J12.
A Computer running a Microsoft Windows operating system equipped with CD-ROM drive
and Ethernet network card.
A CAT5 crossover network cable or an Ethernet hub and standard network cables to
connect the ACU and the computer.
The CD-ROM shipping with the sat-nms ACU19V.
Setting the ACU's IP parameters now is easily done within a few minutes.
1. First install a network cable between the ACU and your computer. If you have a crossover
cable available, this is very easy: simply put the cable into the network connectors of
computer and ACU. Without a crossover cable, you need to connect both, the computer and
the ACU to the same network hub using two standard network cables. It is essential, that the
computer and the ACU are connected to the same network segment, the configuration
program is not able to find the ACU through routers or network switches.