DIAGNOSTICS

LED DIAGNOSTICS

The diagnostic LED on the Remote unit circuit board flashes different patterns to give information about what 

the device is connected to. Most of the information is related to what the unit detects on the sensor cable 

interface.

The diagnostic LED will automatically start the flashing pattern shortly after powering on the Remote unit, and 

once the Remote unit has finished scanning all the attached cables and accessories. The flashing pattern will 

continue to repeat (skipping the channel number) until the Remote unit connects to a Master unit.

The diagnostic LED flashes different colors to convey different information. Red flashes indicate what 

equipment is being scanned, and orange and green flashes indicate the number of items. The LED will flash red 

first, and then orange and/or green. The process will repeat until all the information has been communicated.

LED FLASH SEQUENCE

The diagnostic LED will only flash a specific number of red flashes if the corresponding number is not zero. For 

example, if there are no moisture cables connected to the Master unit, the LED will not flash three red flashes. If 

Figure 5: Diagnostic LED Sequence

Summary of Contents for IntraGrain Bin-Sense

Page 1: ...700052 BS March 2022 Version 1 0 REMOTE UNIT USER MANUAL...

Page 2: ...700052 BS March 2022 Version 1 0 INTENTIONALLY BLANK...

Page 3: ...CERTIFICATIONS 4 MANUFACTURER S WARRANTY 5 HOW TO OBTAIN WARRANTY SERVICE 5 SAFETY 6 STANDARDS 6 OVERVIEW OVERVIEW 7 PACKAGE CONTENTS 7 REMOTE UNIT OVERVIEW 7 INSIDE THE REMOTE UNIT 8 INSTALLATION IN...

Page 4: ...Page 2 March 2022 Version 1 0 www binsense com DIAGNOSTICS LED DIAGNOSTICS 13 Led Flash Sequence 13...

Page 5: ...vice please contact your local dealer For product support troubleshooting or additional questions with your Bin Sense device please contact your local dealer www binsense com locate a dealer or IntraG...

Page 6: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction...

Page 7: ...R This warranty does not cover normal wear of parts or any damage resulting from any of the following negligent use or misuse of the product damage in transport natural disaster improper installation...

Page 8: ...recommended by the manufacturer STANDARDS This manual will use the following standard safety terms and conventions to indicate conditions WARNING INDICATES A HAZARDOUS SITUATION RESULTING IN SERIOUS I...

Page 9: ...grain temperature and moisture data for a single bin on a Bin Sense Live site The Master unit collects data from all the Remote units on a site then sends that data to the Bin Sense website through a...

Page 10: ...IDE THE REMOTE UNIT A PRIMARY MASTER ANTENNA B DIAGNOSTIC PUSHBUTTON C DIAGNOSTIC LED D J2 SPARE SENSOR CABLE CONNECTION E J1 SENSOR CABLE CONNECTION F J11 SOLAR PANEL CONNECTION G VENT H RADIO CHANNE...

Page 11: ...he installation make sure the enclosure lid is closed and latched securely and there are no wires tags or other objects caught between the lid and the enclosure which could cause water ingress REMOTE...

Page 12: ...Page 10 March 2022 Version 1 0 www binsense com 8 Refer to the Bin Sense Live Startup Manual for further instruction on how to get the Bin Sense Live system up and running...

Page 13: ...nnel DIP switches Channels 12 through 23 are available with the default channel being 23 The radio channel only needs to be changed if there are other Bin Sense Live systems installed nearby within ro...

Page 14: ...Page 12 March 2022 Version 1 0 www binsense com INTENTIONALLY BLANK...

Page 15: ...ing pattern will continue to repeat skipping the channel number until the Remote unit connects to a Master unit The diagnostic LED flashes different colors to convey different information Red flashes...

Page 16: ...t is set to radio channel 22 you would expect the following flashing pattern One red flash for total temperature moisture cables followed by two green flashes for number of cables Two red flashes for...

Page 17: ...Manufactured in Canada by Head Office IntraGrain Technologies Inc 118 Husum Road RM of Sherwood SK CANADA S4K 0A4 support intragrain com 1 833 570 7979 www binsense com...

Reviews: