Calf-Star Milk Jug
8
4. I
nstallatIon
^
WARNING
Prevent serious injury or death.
Electrical and mechanical installation
must be performed by qualified
technicians.
Installation must conform to all national,
local, and provincial codes and standards.
4.1 p
osItIon
m
aCHIne
^
WARNING
Prevent serious injury or death.
Use adequate lifting devices to setup and
install equipment.
Use of inadequate equipment may result
in serious injury or death.
Position machine on level surface. If connecting to
an automatic calf feeding system, mount near inlet of
automatic calf feeder.
4.2 W
ater
C
onneCtIons
Note: Water supply must deliver a minimum of 30 psi
(207 kPa) and 5 gpm (19 lpm) of water.
Connect hot water supply to water inlet (A). Connect
cold water supply to water inlet (B).
A
B
4.3 e
leCtrICal
C
onneCtIons
^
WARNING
Prevent serious injury or death.
Electrical installation must be performed
by qualified technicians.
Installation must conform to all national,
local, and provincial codes and standards.
Electrical installation must be performed by a qualified
electrical technician. Electrical supply must be 220
VAC, 20 amp.
4.4 d
etergent
p
ump
C
onneCtIon
Note: Verify the dip tube goes all the way to the
bottom of chemical container.
Connect chemical hose to pump (A). Use an acid
based detergent (one step) for washing.
A