Calex LCT-485 Operator'S Manual Download Page 6

6

Address

R/W

Description

Default
value

Min.
value

Max.
value

0x00 (0)

-

[RESERVED]

-

-

-

0x01 (1)

R

Sensor ID (length: 2 words):
Bits 0..19 - Serial number
Bits 20..23 - Sensor field of view
(0=2:1, 1=15:1, 2=30:1)
Bits 24..27 - Sensor type (A= ExTemp)
Bits 28..31 - Reserved

-

-

-

0x03 (3)

R

Unfiltered object temperature

-

-

-

0x04 (4)

R

Sensor temperature

-

-

-

0x05 (5)

R

Maximum hold temperature

-

-

-

0x06 (6)

R

Minimum hold temperature

-

-

-

0x07 (7)

R

Average temperature

-

-

-

0x08 (8)

R

Filtered object temperature

-

-

-

0x09 (9)

-

[RESERVED]

-

-

-

0x0A (10)

R/W

Emissivity setting (1 LSB = 0.0001)

9500

2000

10000

0x0B (11)

R/W

Reflected temperature

0

-

-

0x0C (12)

R/W

Sensor status:
Bits 0..1 - Reserved
Bit 2 - Hold processing on (1) / off (0)
Bit 3 - Hold peaks (1) / valleys (0)
Bits 4..6 - Reserved
Bit 7 - Reflected energy
compensation on (1) / off (0)
Bits 8..15 - Reserved

3

-

-

0x0D (13)

R/W

Average period (1 LSB = 250 ms)

1

0

240

0x0E (14)

R/W

Hold period (1 LSB = 250 ms)

1

0

4800

0x0F (15)

R/W

Temperature at 4mA

0

-200

9000

0x10 (16)

R/W

Temperature at 20mA

5000

800

10000

0x11 (17)
to
0xCF (207)

-

[RESERVED]

-

-

-

LIST OF MODBUS REGISTERS (EXTEMP REGISTERS)

Interface

Baud rate

1200 bps to 57600 bps,
detected automatically

Format (Bits)

8 data, odd/even/no parity, 1
or 2 stop bits

Reply delay (at
9600 baud)

ExTemp registers: 1 s max
LCT-485 registers:
30 ms (single register)
50 ms (whole address space)

Supported Functions

Read register
(R)

0x03, 0x04

Write single
register (W)

0x06

Write multiple
register (W)

0x10

MODBUS OVER SERIAL LINE (RS-485)

Summary of Contents for LCT-485

Page 1: ...LCT 485 RS 485 Network Interface for ExTemp Infrared Temperature Sensor Operator s Guide...

Page 2: ...mm Communications Isolated RS 485 Modbus RTU Slave Dimensions 114 d x 18 w x 107 h mm approx Connections Screw terminals for RS 485 power and sensor loop suitable for conductors 0 2 to 2 5 mm Supply v...

Page 3: ...dbus repeater allows longer cable on the Master side Connections with Intrinsically Safe Isolator Connections with Zener Barrier LCT 485 LCT 485 4 270 1 13 14 13 14 12 12 11 11 2 3 IS Isolator Power S...

Page 4: ...onnections RS 485 Modbus Network All the below connections are on the safe side of the Intrinsically Safe isolator or barrier 4 Ensure the distance between each device and the network bus is as short...

Page 5: ...peration by completing the following simple steps 1 Turn on the power supply 2 Turn on the indicator if fitted 3 Send a test message to confirm communications with LCT 485 are good we recommend readin...

Page 6: ...Reserved Bit 2 Hold processing on 1 off 0 Bit 3 Hold peaks 1 valleys 0 Bits 4 6 Reserved Bit 7 Reflected energy compensation on 1 off 0 Bits 8 15 Reserved 3 0x0D 13 R W Average period 1 LSB 250 ms 1...

Page 7: ...will automatically measure and set the baud rate It will then try all the possible combinations of stop bit and parity settings until it finds the correct values 4 The LCT 485 will detect when good co...

Page 8: ...help contact us for further advice TROUBLESHOOTING Symptom Probable Cause Solution No communications No power to the device Check the power supply and wiring Incorrect Modbus Slave address Check the...

Reviews: