THE ENVIRONMENT 

 

The symbol attached to the appliance and illustrated opposite indicates that the product is subject to separate collection for electrical 
appliances. At the end of its life, the appliance cannot be disposed of with normal household waste, it must be taken to a specific local 
collection point or returned to the distributor when a new appliance of the same type for the same use is purchased. 
The separate collection of electrical and electronic equipment is part of a policy to safeguard, protect and improve the quality of the 
environment and to avoid potential harmful effects on human health due to the presence of hazardous substances as classified by 
European directives. 

 

CAUTION: Inappropriate disposal of the appliance will result in sanctions. 

 

CHARACTERISTICS OF THE RADIATOR 

 

IP CLASS: see the label on the radiator. 
INSULATION CLASS: see the label on the radiator. 
The radiator consists of a metal body which contains fluid for the internal transmission of heat consisting of a mixture of water and 
antifreeze specifically for this type of use. 

 

M1 / M1CR - M2 / M2CR 

 

Electric control for towel warmer 

 

M1 / M2 is a digital chrono-thermostat for the control of electric towel warmers. 
Thanks to an external sensor, it is able to maintain the desired room temperature. 
It has a simple and modern design, suitable for all decors and types of towel warmer. It is easy to install 
and is available in different colours. 
M1 / M2 is a certified product. 

 

Functions 
Six different operating modes: 
Comfort, Night, Antifreeze, Fil-pilot, Chrono, Timer 2h and Stand-by. 

• Comfort mode 

The thermostat maintains the room temperature at the value set by the user. 

• Night mode 

The thermostat keeps the temperature at a lower value than the Comfort temperature. 

• Antifreeze mode 

The thermostat keeps the room temperature above 7°C. 

• Fil-Pilot mode 

The operation of the electronic control is decided by 

the signal sent by the “Fil-Pilot” system. 

• Chrono mode 

The control works according to a daily programme repeated on a weekly basis, that can be set by the user. 

• "2h Timer” mode 

The electronic control activates the heating element for two hours regardless of the temperature setting. At the end of 
this period, the thermostat returns to the previously set operating mode. 
During the two hours, for safety reasons, the room temperature will be regulated not to exceed 32°C. 

• Stand-by mode 

The control works according to a daily programme repeated on a weekly basis, that can be set by the user. 

Colours available: 

 

- White (RAL9003) 
- Chrome 

 

 

 

OTHER INFORMATION 

 

- Large backlit display showing the temperature setting, time, programming and the mode/function set. 
- All modes/functions can be set using the IR remote control (optional). 
- Daily and weekly programme settable by the user to suit their needs. 

“Open window sensor” function: if this function is active, it deactivates the heating element of the towel warmer when the window of the room is 
opened, for a maximum of 30 minutes, saving energy . 

 

CERTIFICATIONS 

 

- Eco-design Directive for Energy 

- Using Products, 2005/32/EC (<0,5W) 

- EN60335-1:2012 

- EN60335-2-30:2011 

- EN60335-2-43:2008 

- EN61000-3-2:2004 

- EN61000-3-3:1995 

- EN50366:2003 

- EN55014-1:2008 

-EN55014-2:1998 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

CALEIDO srl . via Pablo Neruda, 52/a . 25020 Flero (BS) . Italy 
Tel +39 030 2530054 - Fax +39 030 2530533 
[email protected] 

caleido.it 

Summary of Contents for M1/M1CR

Page 1: ...e screws and plugs supplied or replace them with others which have the same or better mechanical properties CAUTION This appliance is only intended for heating textiles washed in water CAUTION If anti...

Page 2: ...above warnings into consideration the radiator can be installed in areas 2 and 3 as shown in Figure 1 INSTALLING THE RADIATOR The radiator must not be installed in a niche or under a socket Any eleme...

Page 3: ...imer 2h and Stand by Comfort mode The thermostat maintains the room temperature at the value set by the user Night mode The thermostat keeps the temperature at a lower value than the Comfort temperatu...

Page 4: ...I only Room temperature sensor 10KOhm at 25 C Type NTC Power cord H05VVF HAR L 900mm 3x1mmq Class II Fil pilot 2x1mmq Class II 3x1mmq Class I Colours available White RAL9003 White RAL9003 cable Chrome...

Page 5: ...e premature destruction of the heating element could damage the radiator 7 Ensure that the power of the heating element does not exceed the power of the controller see technical plate 8 When installed...

Page 6: ...ins the temperature 3 5 C below the Comfort temperature 4 Anti freeze prevents the temperature from falling below 7 C 5 Eco 1 maintains the temperature 1 C below the Comfort temperature 6 Eco 2 mainta...

Page 7: ...nctions described below 1 Standby switches off the heating element thermostat stays on 2 Comfort maintains the Comfort temperature set by the user 3 Eco maintains the ambient temperature 3 5 C below t...

Page 8: ...og button to confirm and return to stand by mode When the function is activated the open window symbol remains permanently lit When the device detects the open window the symbol flashes When the funct...

Reviews: