Operating Instructions
DC100 Internal Debeader Camera
05
03. Operation
Instructions for Use
1. Open cameras clamping assembly by loosening the clamp
adjustment handle. Attach to the drive rod closest to the cutting tool.
2. Mount camera bracket with camera matching the orientation of the
cutting head.
3. Turn on the monitor and camera to confirm camera placement. The
camera is adjustable on both the X and Y axis to allow the user to
achieve the desired placement.
4. Monitor image is inverted by default, to change go to options and
rotate display until it flips to the desired orientation.
5. Carry out debeading operations as per usual. The camera will
automatically switch into night vision mode when entering the pipe.
Note:
Try to keep monitor within line of sight of camera for best
reception. Moving monitor during use can cause connectivity issues.
Charging
Both monitor and camera are charged with the supplied charger. Ensure
units are switched into the OFF position to allow charging. Units can
be switched back into the ON position at any time to check the charge
level using the LED indicators on the units themselves. When units are
fully charged, the charge status indicator on the charger will turn from
red to green.
Storage
IMPORTANT! When not in use always:
1. Ensure the camera and monitor are clean and dry before storing.
2. Store the camera in the case provided.
Routine Maintenance
1. Check for correct movement and operation regularly.
2. It is important to ensure all components are present and in
serviceable condition.