SPA TROUBLESHOOTING

Page 18

• Reset circuit breaker.

• Reset GFCI.

• Let cool for 1 hour.  Motor overload will reset 

automatically.  If problem persists, contact your 
Caldera dealer.

• Disconnect spa and contact your Caldera dealer.

• Add water to normal level (1 inch above highest 

jet).

• Open all knife valves.

• Open or clean air valve.

• Add water to normal level (1 inch above highest 

jet).

• Clean filter cartridge.

• Open all knife valves.

• Remove jet face eyeball and clean orifice.

•  Clean suction cover or skimmer basket.

• Set control panel to a higher temperature.

• Align spa cover.

• Switch to standard mode and/or lengthen filter

cycles.

• Clean filter cartridge.

•  Circuit breaker tripped or OFF.

•  Motor overload condition.

•  Control switch failure.

•  Low water level.

•  Knife valves closed.

•  Air control valve closed or blocked.

•  Low water level.

•  Dirty filter cartridge.

•  Knife valves partially or fully closed.

•  Jet blocked.

•  Clogged suction or skimmer basket.

•  Temperature set too low.

•  Spa cover improperly positioned.

•  Filter cycles too short in Economy mode.

•  Dirty filter cartridge.

If your spa doesn’t seem to be working the way you believe it should, please review the “START-UP” and “OPERATION”
instructions in this manual.  If this doesn’t help you correct the problem, follow the appropriate instructions below.  If
the problem still is not resolved, call your Caldera dealer.

Nothing works, Blank LCD
screen

Noisy pump or Motor

Pump motor will not function

Pump motor runs, but low or
no water/jet pressure

Spa not heating properly

•  Sand or grit inside valve.

•  Clean and lubricate valve per instructions on 

page 12.

Power Diverters are difficult
to turn

SYMPTOM

PROBABLE CAUSE

SOLUTIONS

Upon filling or refilling the spa, if a pump is operating and water is not flowing from any of its jets,
the pump may not be properly primed.  To correct, refer to the “Equipment Compartment” illustra-
tion on page 13 and perform the following procedures:

• Turn off power to the spa at the breaker and remove the equipment compartment door.

• Loosen the union on the top of the pump to allow the air to escape.  When water is present, 

hand-tighten the union.

• Turn power back on, activate the pump and check to make sure union is tight enough to keep it

from leaking.

Priming the pump

Summary of Contents for Paradise Series

Page 1: ...PARADISE SERIES PORTABLE SPA OWNER S MANUAL GENEVA NIAGARA HAWAIIAN TAHITIAN MARTINIQUE KAUAI QUALITY SPAS AND GAZEBOS SINCE 1976...

Page 2: ...your spa water first time 15 3 day a week spa care program 15 SPA TROUBLESHOOTING Basic Troubleshooting 18 LCD messages 19 WATER MAINTENANCE Water purification with Ozone 16 Alkalinity Table 16 pH Le...

Page 3: ...not addressed in this manual call your Caldera dealer and he or she will be happy to assist you Pictured below are the Caldera Data labels that are locat ed in the spa equipment compartment Locate an...

Page 4: ...er temperatures between 1000 F and 1040 F are considered safe for a healthy adult Lower water tem peratures are recommended for extended use exceeding 10 15 minutes and for young children G Since exce...

Page 5: ...preferred so that rain water and water spillover will run off and not puddle underneath the spa water under the spa for long peri ods of time may cause the wood to deteriorate Other options are brick...

Page 6: ...is located on the back of the Control Module access panel Page 4 240 VOLT INSTALLATION Your spa contains a Control Module designed to operate at 240V 60Hz Installation of a 50 amp dedicated circuit is...

Page 7: ...s directed by your Caldera dealer by the instructions contained in your spa chemical kit or in the section titled BALANCING THE SPA WATER on page 15 6 SET TEMPERATURE Your spa has been pre set to auto...

Page 8: ...eeping the cover in place any time the spa is not in use will reduce the amount of time the heater oper ates thereby minimizing operating costs DANGER RISK OF INJURY Never leave a spa uncovered or una...

Page 9: ...aSsage jets allow you to regu late the force of the massage Rotate the fascia ring clockwise to reduce the force or counter clockwise to increase the force Notice that turing off the flow to some jets...

Page 10: ...and again for the dimmest setting Press the touch pad a fourth time to turn off the light The light automatically turns off after 4 hours of operation The MODE touch pad switches between the standard...

Page 11: ...E SKIM FILTER CYCLES START TIMES The first cycle starts five to ten minutes after the time of day when the power to your spa was last turned on at the circuit breaker or GFCI The second cycle begins t...

Page 12: ...ict water flow If the filter is not cleaned on a regular basis the filter may clog and restrict water flow which causes improp er filtration and poor jet performance See FILTER CARTRIDGE REMOVAL AND C...

Page 13: ...2 Hydro jet pump 1 K Air pump L Drain hose with drain cap M Temperature sensor N Underwater light O Spa water heater P Pump drain plugs Q Ozone injector Option TYPICAL EQUIPMENT COMPARTMENT MARTINIQU...

Page 14: ...push ON or pull OFF of the spa light SPA LIGHT BULB REPLACEMENT 1 Turn OFF the power to the spa 2 Remove the equipment compartment access door 3 Locate the rear of the spa light see EQUIPMENT LOCATION...

Page 15: ...rable to switch the spa to ECONOMY mode When in ECON OMY mode the spa water temperature is maintained within 200 F of the set temperature The automatic filter cycles along with occa sional chemical tr...

Page 16: ...pening of the filter compartment note that air escapes through one of the suction openings in the footwell Close this suction open ing by installing a 1 1 2 NPT freeze plug available from a hardware s...

Page 17: ...until the Alkalinity The instructions below will assist you with balancing the spa water for the first time You will need the following items to balance your spa water 1 3 Way Test Strips 2 Spa Up an...

Page 18: ...DO NOT splash pH increase additives on the redwood cabinet during pH adjustment Many pH increase addi tives will cause redwood to turn dark by pulling the tannin reddish color in redwood out of the w...

Page 19: ...ill Excessive organics Shock with RENEW Organic Buildup Scum Body oils and dirt Wipe off scum with a clean rag Depending on Ring Around The Tub severity drain spa use a spa surface and tile cleaner to...

Page 20: ...my mode Dirty filter cartridge If your spa doesn t seem to be working the way you believe it should please review the START UP and OPERATION instructions in this manual If this doesn t help you correc...

Page 21: ...ng contact your Caldera dealer Flow switch constantly displayed An air lock may have occurred refer to PRIMING THE PUMP S on page 18 for priming instructions or a flow switch has malfunctioned Contact...

Page 22: ...Page 20 NOTES...

Page 23: ...Page 21 NOTES...

Page 24: ...single speed 240V 1 hp 240V 240V 50 Amp 240V 4 0 kW 120V 12V 75 sq ft cartridge 84 in x 84 in x 36 in 360 gal 706 lbs 3 694 lbs 1 5 hp 2 speed 240V 1 5 hp single speed 240V 1 hp 240V 240V 50 Amp 240V...

Reviews: