background image

P

REXISO

 X2 Q

UICK

 S

TART

 G

UIDE

 — 7

 TROUBLESHOOTING

• If the laser remains lit, or the value in the 

Main Display

 keeps changing, 

flashing, or showing “

trc

” you are in 

Continuous Measure

 mode. Press 

On/

Measure

 

 

(Key 1) once to exit this mode.

• If the message 

Error

 does not disappear after switching 

on

 and 

off

 the device 

repeatedly, contact Calculated Industries.

• If the message 

InFo

 appears with a number, follow the instructions in the fol

-

lowing table.

No. 

Cause 

Remedy 

   

 

204 

Calculation error 

Measure again.

252 

Temperature too high 

Let the device cool down.

253 

Temperature too low  

Warm the device up.

255 

Reception signal too weak,  

Change target surface (e.g., white paper).

 

measuring time too long

256 

Input signal too high 

Change target surface (e.g., white paper)

257 

Measuring error, 

Shadow the target area.

 

too much background light

258  

Measurement outside 

Target is beyond range. 

 

of the measuring range 

Move closer to target.

260 

Laser beam interrupted 

Repeat the measurement.

 SPECIFICATIONS

Measuring Range 

4” (10 cm) to 100’ (30.5 m)

Accuracy 

+/- 1/8” (3 mm) or better over entire range

Smallest unit displayed  

1/16 (1 mm)

Laser class  

2

Laser type  

635 nm, < 1 mW

Automatic shut-off  

After 3 minutes

Continuous measuring  

Yes

Addition/Subtraction  

Yes

Area  

Yes

Volume 

Yes

Pythagoras (Indirect)  

Yes

Metric and Imperial Units 

Yes

Dimensions 

4.75 x 2 x 1” (118 x 50 x 26 mm)

Battery life 

Up to 3,000 measurements

Weight  

3.22 ounces (100g)

Temperature range:

- Storage 

-13°F to +158°F (-25°C to +70°C)

- Operation 

32°F to +104°F (0°C to +40°C)

Summary of Contents for PREXISO X2

Page 1: ...Quick Start Guide Model 3350...

Page 2: ...ractions Exponents Fractions Exponents Units Units Key 1 On Measure distance Key 2 Area Volume Pythagoras Area Volume Pythagoras display Measuring plane display Addition Subtraction display Key 5 Add...

Page 3: ...ls screwdriver etc Make sure that the device is not modi ed Avoid using accessories that are not recommended by the manufacturer Do not aim the laser beam at shiny re ective surfaces Avoid aiming dire...

Page 4: ...accurate measurements Perform control measurements periodically Perform control measurements before and after important measurements Switching on off Key 1 Key 3 Switch on the device by pressing Clea...

Page 5: ...ci c desired distances to be determined Hold On Measure Key 1 for several seconds Continuous measuring starts and display shows trc Press On Measure Key 1 brie y Continuous measuring stops The value l...

Page 6: ...distance e g height The result is shown in the Main Display and the last distance measured is shown in the Secondary Display Pythagoras Indirect Press Area Volume Pythagoras key 2 three times The Pyt...

Page 7: ...white paper measuring time too long 256 Input signal too high Change target surface e g white paper 257 Measuring error Shadow the target area too much background light 258 Measurement outside Target...

Page 8: ...operating ELECTROMAGNETIC COMPATIBILITY EMC Warning Possible disturbance of other devices e g safety equipment medical equipment due to electromagnetic radiation Observe the safety instructions of the...

Page 9: ...to the website listed below 4 If you believe you need to return your product please call a Calculated Industries representative between the hours of 8 00am and 4 00pm Pacific Time for additional info...

Page 10: ...s Disclaimer CI MAKES NO WARRANTY OR REPRESENTATION EITHER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCT S QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AS A RESULT THIS PRO...

Page 11: ...ractions Exponents Fractions Exponents Units Units Key 1 On Measure distance Key 2 Area Volume Pythagoras Area Volume Pythagoras display Measuring plane display Addition Subtraction display Key 5 Add...

Page 12: ...12 PREXISO X2 QUICK START GUIDE Printed in U S A 1 12 QSG3350E C...

Reviews: