background image

U

SER’S

G

UIDE

Area Take-Off Tool and Digitizing System

Model
#6260

Summary of Contents for 6260

Page 1: ...USER S GUIDE Area Take Off Tool and Digitizing System Model 6260...

Page 2: ...LYGONS 22 MEASURING TAKE OUTS 24 MEASURING COMPLEX POLYGONS 26 MEASURING IRREGULAR SHAPES 28 MEASURING ARCS AND CIRCLES 30 MEASURING ARCS 32 MEASURING 3 POINT CIRCLES 34 CUSTOM SCALES 36 SETTING A MEA...

Page 3: ...osts for measuring storing and calculating perimeters areas and volumes from architectural plans and other types of scaled drawings Use the Ultra Scale MasterPro to calculate the area and volume of ir...

Page 4: ...CONTENTS Your package contains the following pieces Female End Cap 2 ULTRA SCALE MASTER PRO Long Reflector Bar USB Cable Ultra Scale Master Pro model 6260 Puck Four AAA batteries already installed Cor...

Page 5: ...User s Guide Quick Reference Guide and Quick Setup Sheet Male End Cap USER S GUIDE 3 Short Reflector Bar Long Reflector Bar Carrying Case...

Page 6: ...the first Long Reflector Bar The Female End Cap is preinstalled for a Right Hand configuration 1 Insert the male end of the Corner Connector into the female end of the first Long Reflector Bar 2 Inse...

Page 7: ...L ASSEMBLY The ultrasonic beams are sent from the left arm of the Puck to the top bar then reflected back and from the right arm of the Puck to the side bar then reflected back as shown above The Puck...

Page 8: ...eflector Bar into the female end of the Short Reflector Bar 3 4 Insert the male end of the Short Reflector Bar into the Female Bar End Cap 4 LEFT HAND ASSEMBLY Assemble the reflector bars as shown Ali...

Page 9: ...the top bar and the left arm remains parallel to the side bar as shown above 1 Insert the male end of the first Long Reflector Bar into the female end of the Corner Connector 1 1 Insert male end of th...

Page 10: ...ck should maintain a 45 angle within the bars while measuring 4 Ensure that the measuring surface is flat and smooth Make sure there are no folds tears or raised areas of the plans 5 Make sure there a...

Page 11: ...Right Hand Configuration Shown USER S GUIDE 9...

Page 12: ...CLOSE Completes the Polygon or a 2 Point Circle and displays the calculated area Results are identified as negative values When measuring a Polygon this key connects the last measured point to the st...

Page 13: ...Important Notes regarding the ON CLEAR key If ON CLEAR is pressed during measurement the last measured point is undone and the previous measurement is displayed A second press of ON CLEAR ends the mea...

Page 14: ...ed presses of UNDO SET Used in conjunction with the HEIGHT and SCALE keys to set a Height or Custom Scale See Setting a Height and Setting Custom Scale sections Also used to access secondary functions...

Page 15: ...ale Master Pro will auto close three point Arc or Circle measurements MR Memory Recall First press displays the accumulative Memory value second consecutive press displays Memory Count third consecuti...

Page 16: ...ALE Used to move back through the list of available scales DIGITIZER Sets unit into digitizing mode for use with digitizing software see Digitizer Mode section RESET Clears all values and resets all s...

Page 17: ...ent section SET UNITS Used to move back through the list of available units of measurement PREFS Preferences Accesses Preference settings see Preferences section HEIGHT Displays stored height Also use...

Page 18: ...values and important messages Unit legend is a description of displayed values i e Square Feet Inch USING THEULTRA SCALE MASTER PRO UNDERSTANDING THE LCD Low Battery Indicator The area immediately bel...

Page 19: ...in Metric Mode MET will appear in the scale area of the display to indicate that it is in Metric Mode IMPERIAL Modes Scales Architectural ARCH 1 Foot Engineering I ENGI 1 Inch Engineering II ENGII 1...

Page 20: ...ape that is not a Square Rectangle or Triangle Only one shape can be measured at a time For a Polygon or Polyline only the last 64 measured sides can be displayed when viewing side Lengths via the D P...

Page 21: ...of a curve CIRCLE A plane curve equidistant from a fixed center ILLEGAL SHAPE The Area and Volume can not be calculated for a shape containing bisecting lines The Area and Volume of the shapes result...

Page 22: ...er the first point and press the MEASURE key 2 Move to the second point and press the MEASURE key The display will show the Length of the first line segment 3 Move to the third point and press the MEA...

Page 23: ...l scroll back and forth through the values 4 5 Press the D Pad right 4 to display the individual side Lengths in sequential order beginning with side one Repeated presses of the D Pad left 3 will scro...

Page 24: ...int and press the MEASURE key The display will show the Length of the first line segment 3 Move to the third point and press the MEASURE key The display will show the accumulated Length of the two mea...

Page 25: ...lume and Height do not display if a Height has not been set For this example a Height of eight Feet was used See Setting a Height section for instructions on setting a Height AREA PERIMETER WALL AREA...

Page 26: ...and press the MEASURE key The display will show the Length of the first line segment 3 Move to the third point and press the MEASURE key The display will show the accumulated Length of the two measur...

Page 27: ...emory then repeat steps 1 through 4 for the Take Out 5 7 Press the CLOSE key followed by the SET then M keys Now press the MR key to display the Adjusted Area Press the SET then MR keys to clear the M...

Page 28: ...hird point and press the MEASURE key 4 Move to the fourth point and press the MEASURE key 5 Move to the fifth point and press the MEASURE key 6 Move to the sixth point and press the MEASURE key 7 Move...

Page 29: ...s of the D Pad down 6 or up 5 will scroll back and forth through the values Wall Area Volume and Height do not display if a Height has not been set For this example a Height of eight Feet was used See...

Page 30: ...hird point and press the MEASURE key 4 Move to the fourth point and press the MEASURE key 5 Move to the fifth point and press the MEASURE key 6 Move to the sixth point and press the MEASURE key 7 Move...

Page 31: ...s of the D Pad down 6 or up 5 will scroll back and forth through the values Wall Area Volume and Height do not display if a Height has not been set For this example a Height of eight Feet was used See...

Page 32: ...red Height Only displayed if a Height has been stored Arc Length The total Length of the Arc Arc Length Wall Area The total of the Arc Length multiplied by the stored Height Only displayed if a Height...

Page 33: ...as been stored Circle Radius The linear distance from the center to the outside of the Circle Half of the Circle Diameter Circle Diameter The linear distance across the center of the Circle Circle Are...

Page 34: ...e crosshairs over the Start Point of the Arc and press the MEASURE key 2 Move to the High Point of the Arc and press the MEASURE key 3 Move to the Final Point of the Arc and press the MEASURE key You...

Page 35: ...t Continuous presses of the D Pad down 6 or up 5 will scroll back and forth through the values Arc Wall Area Arc Volume and Height do not display if a Height has not been set For this example a Height...

Page 36: ...f the Circle and press the MEASURE key 2 Move to the second point of the Circle and press the MEASURE key 3 Move to the third point of the Circle and press the MEASURE key You must identify the measur...

Page 37: ...Circle Volume and Height do not display if a Height has not been set For this example a Height of eight Feet was used See Setting a Height section for instructions on setting a Height 4 5 Press the D...

Page 38: ...ored in its place or until an All Clear or Reset is performed Switching between Imperial and Metric Modes does not clear stored Custom Scales SETTING A MEASURED CUSTOM SCALE CUSTOM SCALES 1 Press MODE...

Page 39: ...d up 5 or down 6 to increase or decrease the selected digit 8 To store the Custom Scale press SET or SCALE To confirm the scale has been set Scl Set is displayed for one second Stored Custom Scales di...

Page 40: ...s 4 Use D Pad right 4 to begin value entry mode The selected digit begins flashing indicating that it is ready to be changed Use D Pad right 4 and left 3 to move between the digits 5 Use D Pad up 5 or...

Page 41: ...right 4 to begin value entry mode The selected digit begins flashing indicating that it is ready to be changed Use D Pad right 4 and left 3 to move between the digits 4 Use D Pad up 5 or down 6 to inc...

Page 42: ...ting the displayed value If the value is too large to be displayed in the units selected the display will remain unchanged maintaining the same value and units until the value is converted to a unit t...

Page 43: ...de Display will show digi On It will remain in Digitizer Mode until the DIGITIZER key is pressed again or when a manual reset is performed see Reset section WHILE IN DIGITIZER MODE The following keys...

Page 44: ...ect your Ultra Scale MasterPro to your PC SYSTEM REQUIREMENTS Windows 2000 XP Vista Operating Systems One USB port Note When connected to a PC a small PC shaped icon will appear at the upper right sid...

Page 45: ...NG COMMAND Enter Performs an ENTER command after value is sent to the PC Tab Performs a TAB command after value is sent to the PC Left Performs a LEFT command after value is sent to the PC Right Perfo...

Page 46: ...isplays SEnt PC for one second each time a value is sent to the PC successfully Note The decimal equivalent of the value in the main display of the Puck is sent to the PC each time PC Send is pressed...

Page 47: ...te whole digits from decimal digits e g 1 234 00 Euro Displays commas and decimals in standard European format commas separate whole digits from fractional digits and decimals separate groups of three...

Page 48: ...rms no action after value is sent o the PC 6 DIGITIZER OPERATION ORIENTATION Right Sets to right hand operation orientation while in Digitizer Mode See Right Hand Assembly section Left Sets to left ha...

Page 49: ...occurs when attempting to store values of different dimensions into Memory OFLO Overflow value is too large to be displayed SEnd Error Not connected to a PC Auto Shut off The Ultra Scale Master Pro i...

Page 50: ...ANTY Warranty Repair Service U S A Calculated Industries CI warrants this product against defects in materials and workmanship for a period of one 1 year from the date of original consumer purchase in...

Page 51: ......

Page 52: ......

Reviews: