Keep in mind, however, this may cause the modem to lose its credentials and become unable to
register to the network.
4.5.2 Activating a CDMA LMU-3030
™ – Sprint
Activating an LMU-3030
™ on the Sprint CDMA network is identical to activating on the Verizon
network.
1. Power on the LMU-3030
™, making sure you can observe the behavior of the Comm LED.
2. Wait until the Comm LED turns solid. This could take up to 5 minutes.
3. If after 5 minutes you observe that the Comm LED transitions from a slow blink to a fast blink
several times (i.e. more than twice) you will need to contact Sprint for further support on account
activation..
Once configured, you may verify that the LMU-3030
’s™ modem has registered to the CDMA network.
Enter:
AT$APP COMM STATUS?
The response should be similar to:
CDMA Service:
IS-2000
Connection:
Yes
RSSI:
-80 dBm
Channel:
0
Band:Side:
800:B
Base Station ID: 0
Network ID:
0
System ID:
4145
ESN (Modem S/N: 2676319948 [9F8566CC]
Phone Number:
1234567890
IMSI:
310001234567890
CarrierConfig:
1
The Phone Number field should match the <Phone Number> value you used in step 3 or 4. The last 10