background image

819

1XRT

 

Serial

 

Cellular

 

Data

 

Modem

 

7

 

CONFIGURING

 

THE

 

MODEM

  

1.

 

Click

 

on

 

Start

 → 

Settings

 → 

Control

 

Panel.

 

Select

 

Phone

 

and

 

Modem

 

Options

.

 

2.

 

Click

 

New

.

  

3.

 

In

 

Location

 

Name

,

 

enter

 

a

 

name

 

to

 

distinguish

 

this

 

connection

 

(i.e.,

 

819

1XRT).

 

Type

 

your

 

area

 

code

 

in

 

the

 

Area

 

Code

 

box.

  

4.

 

Click

 

Apply

 

and

 

OK

.

 

The

 

window

 

should

 

exit

 

out

 

to

 

the

 

Phone

 

and

 

Modem

 

Options

 

box.

 

5.

 

Click

 

the

 

tab

 

at

 

the

 

top

 

titled

 

Modems

.

 

Select

 

the

 

Standard

 

19200

 

bps

 

Modem

 

(or

 

the

 

Kyocera

 

High

Speed

 

Modem

 

if

 

you

 

installed

 

using

 

the

 

driver

 

from

 

the

 

website)

 

and

 

click

 

Properties

.

  

6.

 

Click

 

the

 

Modem

 

Tab

 

at

 

the

 

top

 

of

 

this

 

new

 

box.

 

The

 

box

 

titled

 

Maximum

 

Port

 

Speed

 

should

 

read:

 

115200.

 

If

 

not,

 

scroll

 

down

 

to

 

Select

 

115200

.

 

Click

 

OK

.

 

Click

 

Apply.

 

Click

 

OK

.

 

OPERATIONAL

 

STATES

 

The

 

modem

 

has

 

three

 

operational

 

states:

 

 

ƒ

 

Command

 

State

 

ƒ

 

Online

 

State

 

ƒ

 

Online

 

Command

 

State

 

 

When

 

first

 

powered

 

on,

 

the

 

modem

 

is

 

in

 

the

 

Command

 

State

 

where

 

it

 

is

 

able

 

to

 

accept

 

AT

 

commands.

 

When

 

instructed

 

to

 

dial

 

out

 

or

 

to

 

answer

 

a

 

data

 

call,

 

the

 

phone

 

is

 

in

 

the

 

Online

 

State.

 

ACTIVATING

 

YOUR

 

MODEM

 

1.

 

Connect

 

the

 

modem

 

to

 

an

 

active

 

COM

 

port

 

on

 

a

 

PC

 

with

 

an

 

RS

232

 

9

 

pin

 

straight

 

through

 

cable.

  

2.

 

Attach

 

the

 

antenna

 

and

 

power

 

connector.

 

3.

 

Connect

 

with

 

a

 

Hyper

Terminal

 

session

 

set

 

to

 

115,200,

 

8

 

Bits,

 

No

 

Parity,

 

1

 

Stop

 

Bit,

 

and

 

Hardware

 

Flow

 

Control

 

enabled.

  

Refer

 

to

 

Figure

 

1.

 

 

Summary of Contents for LandCell 819?1XRT

Page 1: ...LandCell 819 1XRT Modem 8 81 19 9 1 1X XR RT T X XX XX X CDMA 1xRTT Serial Cellular Data Modem Quick Start Guide 004 0003 819 Rev 2 Released January 2008 Updated February 2008...

Page 2: ...ty or servicing At the time of publication all data is correct for the operation of the equipment at the voltage and or temperature referred to Performance data indicates typical values related to the...

Page 3: ...distance from your head and body while the modem is in use see below IMPORTANT NOTICE Maintain a distance of at least 20 cm 8 inches between the transmitter s antenna and any person while in use This...

Page 4: ...vicinity of protected personal medical devices i e hearing aids and pacemakers Operation in the presence of other electronic equipment may cause interference if equipment is incorrectly protected Fol...

Page 5: ...g Mount Antenna L2 ANT0001 L2 ANT0003 Power Supply 110 VAC input DC Power Cable L2 PWR0001 L2 PWR0002 Interface Cables Serial Cable L2 CAB0002 AGPS Option Installed AGPS antenna connector 823 7500 501...

Page 6: ...sary modem driver files from our website at www calamp com If you are installing the modem using the drivers from the website refer to the steps listed in the 819 1XRT User Manual SETTING UP THE 819 1...

Page 7: ...Modem Tab at the top of this new box The box titled Maximum Port Speed should read 115200 If not scroll down to Select 115200 Click OK Click Apply Click OK OPERATIONAL STATES The modem has three oper...

Page 8: ...t registered It may take up to 15 seconds after power up to register on the network Once registered a typical response is CSS 1 A 4152 where 1 is the band class 1 800 MHz 2 1900 MHz A F is the band Z...

Page 9: ...rm modem activation by performing a voice call to your cell phone with AT CDV Cell Phone Number use no spaces or angle brackets Your cell phone should ring and display the phone number of the modem Fi...

Page 10: ...iption Direction is DTE relative to DCE Pin Name Direction Description 1 CD Carrier Detect 2 RX Receive Data 3 TX Transmit Data 4 DTR Data Terminal Ready 5 GND System Ground 6 DSR Data Set Ready 7 RTS...

Page 11: ...DN Phone Number From Verizon Without Hyphens AT KWMSID 10 Digit MIN Number From Cellular Carrier Without Hyphens This only needs to be entered if different than the MDN AT KWMODE 2 AT CDV 22899 After...

Page 12: ...ust be manually provisioned with the MDN and MSID The IOTA session will occur and populate the 3GPD parameters If it is the first IOTA session it is called a Network Initiated Initial Provisioning NII...

Page 13: ...these numbers are the same It is very important to program these numbers correctly If they are reversed the modem will not work The MIN is automatically loaded with the MDN number Enter the MDN first...

Page 14: ...hout hyphens AT KWMSID 10 Digit MSID MIN number from cellular carrier without hyphens This is required only if different than the MDN AT KWMODE 2 AT CDV 22803 After issuing the last command listed abo...

Reviews: