Safety Summary

WARNING

 

CAUTION

To avoid personal injury and/or product damage,

 review and comply 

with the following safety precautions. These precautions apply to both 

operating and maintenance personnel and must be followed during all 

phases of operation, service, and repair of this instrument.

Only qualified personnel should use this probe.

 This high voltage 

probe is designed to be used by personnel who are trained, experienced, 

or otherwise qualified to recognize hazardous situations and who are 

trained in the safety precautions necessary to avoid possible injury when 

using such a device. 

This instrument is intended for usage within Measurement Category I 

(CAT I) only. 
Do not exceed 60 seconds of contact with high voltage.

 When 

making contact between this probe and any circuit with voltages ≥8 kV 

DC, ≥5 kVrms AC, or ≥15 kVpk-pk AC, wait for 5 minutes between such 

measurements.

Do not work alone

 when working with high voltages.

Do not apply to the input any potential that exceeds the maximum 

rating of the probe.
For your own safety, inspect the probes

 for cracks and frayed or broken 

leads before each use. If defects are noted, DO NOT USE the probe.

Hands, shoes, floor and work bench must be dry. 
Avoid making measurements under humidity,

 dampness or other 

environmental conditions that might affect safety.

Turn the high voltage source off before connecting or disconnecting

 

the probe whenever possible.

The probe body should be kept clean

 and free of any conductive 

contamination.

Do not remove the probe casing.

 Removal of the probe’s casing may 

Summary of Contents for CT4024

Page 1: ...CT4024 User Manual...

Page 2: ...ategory I CAT I only Do not exceed 60 seconds of contact with high voltage When making contact between this probe and any circuit with voltages 8 kV DC 5 kVrms AC or 15 kVpk pk AC wait for 5 minutes b...

Page 3: ...liquid being spilled on the instrument z z In air temperatures exceeding the specified operating temperatures z z In atmospheric pressures outside the specified altitude limits or where the surroundin...

Page 4: ...or the entire product Compliance Statements Disposal of Old Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This product...

Page 5: ...Overview The Elditest CT4024 is an 8 kV High Voltage divider probe for use with both digital and analog oscilloscopes Features z z Measures up to 8 kV DC ACpk or 6 kVrms AC z z 40 MHz bandwidth z z V...

Page 6: ...4 Connect the divider probe ground lead alligator clip to a good earth ground or reliable chassis ground 5 Before turning on the high voltage source be certain the operator is not touching any part of...

Page 7: ...whenever the probe is connected to or transferred between oscilloscopes The procedure is the same as for a x10 passive probe z Connect the probe to the oscilloscope z Connect probe tip to square wave...

Page 8: ...1028 caltestelectronics com 7 Figure 2 shows how over and under compensated pulse responses will look Figure 2 Over Under Compensation Figure 3 shows a perfectly compensated probe Figure 3 Good Compe...

Page 9: ...fficient 200 ppm C Input Resistance 100 M 5 Rise Time 9 ns Accuracy DC Volts 3 below 8 kV AC Volts 3 at 1 kHz 3 dB 0 to 40 MHz General Cable Length 6 6 ft 2 m Designed for Use in Pollution Degree 2 Op...

Page 10: ...572 1028 caltestelectronics com 9 5 Voltage Derating Curve WARNING When measuring higher frequency signals be sure to comply with the Voltage vs Frequency Derating Curve Figure 4 Voltage Derating Cur...

Page 11: ...ginal purchase Under this warranty Cal Test Electronics is limited to repairing the defective device when returned to the factory shipping charges prepaid within the warranty period Units returned to...

Page 12: ...representative of Cal Test Electronics is authorized to assume any other obligation in connection with the sale and purchase of this device Service If you have a need for calibration or repair service...

Page 13: ...800 572 1028 caltestelectronics com 12 Notes...

Page 14: ...800 572 1028 caltestelectronics com 13...

Page 15: ...800 572 1028 caltestelectronics com 14...

Page 16: ...800 572 1028 caltestelectronics com 15...

Reviews: