20
Appendix
Cal Flame Side Burners
LTR20091082, Rev. A
www.calspas.com
Problem: Plugged orifice
Solution:
Unplug the orifice as follows:
Remove burner rack and brass burner.
•
Using a 7mm socket or socket wrench, remove the
•
brass orifice.
Gently clear any obstruction with a fine wire.
•
Reinstall the orifice and replace the burner racks.
•
If an obstruction is suspected in the control valve, con-
tact your local Cal Flame dealer for assistance.
Problem: Misalignment of Igniter on Burner
Solution:
Check for proper position of the electrode tip, which
•
is next to, but does not touch, the brass burner. It
should be pointing straight up and free of grease to
allow proper sparking.
The ignition wire should be connected firmly to the
•
valve ignition device and electrode. Reattach it if it
has become disconnected. Replace the ignition wire
if it is frayed or cracked.
With the gas supply closed and control knobs set to
•
the off position, check each position igniter individu-
ally for the presence of a spark at the electrode.
Push each knob in fully and rotate it about 1/4 turn
to the left (counter-clockwise) until you hear a loud
click. The trigger hitting the strike block should
produce a blue spark at the electrode tip. Return
control knob to the off position before checking the
next igniter.