1/3

In the current measurement mode input impedance is 5

Therefore, in the current measurement mode, a voltage input

should not be connected to the input terminals, otherwise, the device will be damaged.

W.

To change the input type from

voltage to a current measurement mode, isolate the input before changing the operation mode.

EI141 must not be used in location where measurement category is II, III or IV.

* 34x77mm sized.
* 4 digits display.
* Easy to use by front panel keypad.
* Display scale can be adjusted between -1999 and 4000.
* Decimal point can be adjusted between 1 and 3 digits.
* Measurement unit can be displayed.
* Selectable four different standard input types (0-20mA, 4-20mA, 0-1V, 0-10V)
* User can calibrate the device according to his/her own specified input type.
* Sampling time can be adjusted in four steps.
* Maximum and minimum measurement values are registered.
* The maximum or the minimum values can be hold on the display.
* Current and voltage calibration can be made..
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.

Supply Voltage

Order Code

230V AC +10% -20%

EI141-230VAC

24V AC

10%

EI141-24VAC
EI141-12VAC

EI141-E-05

Input type

0-1V DC voltage

0-10V DC voltage

0-20mA DC current
4-20mA DC current

Input empedance

Approx. 11k

(terminal voltage limits: min. = -2V, max. = 30V)

W

Approx.

(terminal voltage limits: min. = -2V, max. = 30V)

11k

W

Approx. 5

(applicable terminal voltage is max. 50mA.)

W

Approx.

(applicable terminal voltage is max. 50mA.)

5

W

CAL EI141 PROGRAMMABLE INDICATOR

Thank you for choosing the CAL EI141 indicator.

ENVIRONMENTAL CONDITIONS

Height

Max. 2000m

Ambient/storage temperature

Max. relative humidity

0 ... +50°C/-25 ... +70°C (with no icing)

Rated pollution degree

TECHNICAL SPECIFICATIONS

80

up to 31

decreasing linearly 50

at 40

.

%

%

°C

°C

According to EN 60529

Front panel :

IP60

Rear panel :

IP20

Do not use the device in locations subject to corrosive and flammable gases.

Supply

230V AC +%10 -%20, 50/60Hz or 12/24V AC ±%10, 50/60Hz or optional 9-30V DC

.

±%10

Power consumption

Max. 7VA
2.5mm² screw-terminal connections

Wiring
Date retention
EMC
Safety requirements

EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)

EEPROM (Min. 10 years)

EN 61010-1: 2001 (pollution degree 2, overvoltage category II, measurement category I)

ELECTRICAL CHARACTERISTICS

HOUSING

Housing type

Suitable for panel mounting according to DIN 43 700.

Dimensions

W77xH34xD70mm

Weight

Approx. 250g (after packing)

Enclosure material

Self extinguishing plastics

While cleaning the device, solvents (thinner, benzine, acid etc.) or

must not be used.

corrosive materials

0V

±

)

0,5% (of full scale

0V

±

)

0,5% (of full scale

0mA

±

)

0,5% (of full scale

0mA

±

)

0,5% (of full scale

1.1V

14V
25mA
25mA

Min.

Max.

Measurement range Measurement accuracy

SET

CAL

EI141

PROGRAMMABLE INDICATOR

CAL CONTROLS LTD

Tel : +44 (0) 1462 436161

Fax : +44 (0) 1462 451801

e-mail: [email protected]

Web : www.cal-controls.com

Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.

Please read this document carefully before using this product. The guarantee will be invalidated if
the device is damaged by not following instructions detailed in the manual. CAL Controls shall not
be responsible for any damage or losses however caused, which may be experienced as a result
of the installation or use of this product.

9-30V DC SMPS module

EI141-SM

12V AC

10%

Reviews: