9. OPERATION

•  The device is designed for operation inside buildings, at temperatures above 0oC. In low temperatures (be-

low 0ºC) there is a danger of freezing of the medium.

The manufacturer bears no responsibility for damage of the heat exchanger resulting from freezing 

of the medium in the exchanger. It is forbidden to place any objects on the heater or to hang any 

objects on the connecting stubs.

•  The device must be inspected periodically. In the case of incorrect operation of the device it should be 

switched off immediately.

•  It is forbidden to use a damaged device. The manufacturer bears no responsibility for damage resulting from 

the use of a damaged device.

•  If it is necessary to clean the exchanger, be careful not to damage the aluminium lamellas.
•  For the time of performing inspection or cleaning the device, the electrical power supply should be discon-

nected.

•  In case water is drained from the device for a longer period of time, the exchanger tubes should be emptied 

with compressed air

Periodically need to be checked exchanger condition. Exchanger filled with dirt causes in heat output and air flow 
drop. 

If cleaning of heat exchanger is needed use listed  guidelines. 

•  Disconnect power supply of unit. 
•  Dismount inlet grill guard
•  It is recommended to use pressured air to clean the exchanger, air stream need to be directed perpendicular 

to exchanger and moved along lamellas.

•  It is prohibited to use water or sharp items to clean exchanger.

•  Other installed equipment do not need be cleaned.

Outlet lamellas/blades are adjustable /- 10 ° range. By manually setting the angle of the airflow stream, 
you can adjust an air barrier to the conditions around the door opening.

10. CLEANING AND CONSERVATION

11. OUTLET GRILL ADJUSTING

Summary of Contents for SOLANO CEILING-E-100

Page 1: ...AIR CURTAIN TECHNICAL DOCUMENTATION...

Page 2: ...installation electrical connection connection to the heating medium start up repairs and maintenance of air curtains observe the commonly recognized safety standards and regulations 1 TECHNICAL DATA...

Page 3: ...hanger max range 5 m CEILING E 200 curtain with electrical heat exchanger max range 5 m CEILING W temperature increase at inlet air 10o C and heating agent temperature 90 70o C CEILING E temperature i...

Page 4: ...N E 150 1546 mm 600 mm 561 mm 1207 mm 297 mm 84 mm CEILING W N E 200 2034 mm 600 mm 561 mm 1621 mm 297 mm 157 mm step W 100 E 100 N 100 W 150 E 150 N 150 W 200 E 200 N 200 3 2600 m3 h 3500 m3 h 4000...

Page 5: ...7 1 7 2 290 310 316 0 6 0 6 0 7 19 0 18 5 18 0 2 5 2 5 2 6 72 74 75 0 1 0 1 0 1 13 5 13 0 12 5 15 5 7 6 1 6 2 248 266 271 0 5 0 5 0 6 22 5 22 0 21 5 2 1 2 2 2 2 62 63 64 0 1 0 1 0 1 18 0 17 5 17 5 20...

Page 6: ...24 5 PT Qw pw Tp2 PT Qw pw Tp2 Tp1 V kW I h kPa C kW I h kPa C C m3 h Tw1 Tw2 90 70o C Tw1 Tw2 80 60o C 0 4000 4300 5200 27 6 28 7 31 8 1217 1266 1402 11 4 12 2 14 7 20 5 19 5 18 0 23 6 24 6 27 7 1038...

Page 7: ...1 3 5 2 4 6 B A CEILING 100 572 mm 1024 mm CEILING 150 572 mm 1510 mm CEILING 200 572 mm 2000 mm C D E F CEILING 100 133 770 mm 121 mm 561 mm CEILING 150 182 1207 mm 122 mm 561 mm CEILING 200 256 1621...

Page 8: ...8 4 INSTALLATION 7 9 11 13 8 10 12 14...

Page 9: ...nnectors 1xNC i 1xNO Max current resistive 10A inductive 3A Max Power load 300Vac or 250Vdc S V 2 1 2 two way 1 2 valve with actuator IP Insulation class IP20 Power supply 200 240V 50 60Hz Max water t...

Page 10: ...10 5 2 CONNECTING GUIDE 1 3 5 7 2 4 6 8 CEILING B W N CEILING B E...

Page 11: ...umber of set fan speed T signalize of valve set DC signalize of door contact set OPEN CLOSE signalize valve actuator WORK signalize of software working SW3 operating mode switch default settings K1 pr...

Page 12: ...MY 3x1mm2 Air curtain step switch with thermostat S C OMY 5x0 5mm2 Heat heating mode Fan room thermostat deactivated Cool cooling mode Door contact S DS MEC S DS MAG door closed contacts opened door o...

Page 13: ...vercurrent B25 Air curtain step switch with thermostat S C OMY 5x0 5mm2 HEAT heating mode FAN room thermostat deactivated COOL cooling mode Door contact S DS MAG S DS MEC door closed contacts opened d...

Page 14: ...raided wire pair max 50 m Door contact S DS MAG S DS MEC door closed contacts opened door opened contacts closed Valve with actuator S V 3 OMY 3x0 5mm2 or S V 2 OMY 3x0 5mm2 A Exchanger water supply A...

Page 15: ...SOLANO CEILING E 200 min 5x6 mm2 Overcurrent B25 S touch LIYCY 4x0 5mm2 A and B braided wire pair max 50 m Door contact S DS MAG S DS MEC door closed contacts opened door opened contacts closed ATTENT...

Page 16: ...directly Switch 2 on SW3 set In position For MASTER curtain For SLAVE curtain In case to connect several devices to one S TOUCH and independent local work of curtains with door switches use DRV IN DRV...

Page 17: ...17 5 3 7 CONTROL SYSTEM APPLIANCES CHAINING NOTE In last appliance in line dipswitch SW2 has to be switched to the right T120 The maximum length of the connecting cable 50 m LIYCY 3x 0 5 mm2...

Page 18: ...an 0 FAN_SPEED0 Fan is off 1 FAN_SPEED1 1st step of fan is on 2 FAN_SPEED2 2nd step of fan is on 3 FAN_SPEED3 3rd step of fan is on 2 0x06 CurtainHeatRef 0 1 Set value for thermostat 0 HEAT_OFF Curtai...

Page 19: ...It is recommended to install vent valves at the highest point of the system The system should be executed so that in the case of a failure it is possible to disassemble the device For this purpose it...

Page 20: ...me of performing inspection or cleaning the device the electrical power supply should be discon nected In case water is drained from the device for a longer period of time the exchanger tubes should b...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...Made in Poland Made in EU Manufacturer OUEST ISOL VENTIL Z I de la Rangle 27460 ALIZAY...

Reviews: