Cairox CHRU-L300 Technical Manual Download Page 5

 

User manual of remote controller 

Button function introduction: 

1. Press “on” to turn on the ventilator.
2. Press “off” to turn off the ventilator.
3. Press “Lock” to turn off the display,

repress again to turn on the display.

4. Press “Hour”, “Hour” part at the top right corner of the ventilator screen starts twin-

kling, then press “+” to increase time, press “-” to decrease time, repress “Hour” but-
ton to save time and exit.

5. Press “Minute”, “Minute” part at the top right corner of the ventilator screen starts twin-

kling, then press “+” to increase time, press “-” to decrease time, repress “Minute”
button to save and exit.

Remark: During twinkling, if no operation in 15s, twinkling ends and save setting 

automatically.

6. The “-”, “+” buttons are used in coordination with other buttons.
7. The function of “Sleep” button is similar to “Sleep” button on ventilator.
8. The function of “Auto” button is similar to “Auto” button on ventilator.
9. Timer: Press “Timer”, timer mode starts, time at the top right corner of the machine

screen twinkles. Press “+” to increase time and “-” to decrease time in interval of 30
minutes, the longest timing is 8 hours, default timing is 00:00; Repress “Timer” button
to save and exit timer setting, top right corner of the ventilator displays current time
again.

Remark: During twinkling, if no operation in 15s, twinkling ends and save setting 

automatically.  

     

After timer setting finished, if repress “Timer” button, top right corner of the display 

shows remaining time for the timer setting, at this time it is ok to set the timer again. 
To cancel timer function, set the time to 00:00.  

10. The function of “PURE L”, “PURE M”, “PURE H” is similar to that on the ventilator.

Operation Instructions

7

 

Installation Instructions

Flexible duct installation

Inner diameter

 

of 

the duct (mm)

Outer diameter

 

of the 

duct (mm)

Remark

150

170 

Fresh air and exhaust air vent 

diameter is 150mm 

Note

The hole diameter should be changed according to the actual flexible duct 

size. The 2 holes should face downward toward the outside 5

°

1. According to the vents size and recommended hole size to select suitable flexible duct,
recommended inner and outer diameter of the duct is as below.

3. According to the wall depth, choose the
suitable duct length, connect the ducts to
the ventilator vents and fix the ducts by
sealing ring.

4. Put the other end of the ducts to the
holes, during this process, user can slightly
move the ventilator until the location well
enough.

2. According to the ventilation project design, choose the suitable location, to drill 2 holes
on wall for fresh air inlet and exhaust air outlet, recommended hole sizes are diameter
175mm, please refer to the ventilator “dimension” before drilling the holes.

5. Pull out the ducts from outside and con-
nect the ducts to the rain covers, then fix
the ducts and rain covers by sealing ring.

8

Summary of Contents for CHRU-L300

Page 1: ...n s a n d O p e r a t i o n I n s t r u c t i o n s 4 5 O p e r a t i o n I n s t r u c t i o n s 6 7 I n s t a l l a t i o n I n s t r u c t i o n s 8 9 M a i n t e n a n c e 1 0 1 1 F a i l u r e D...

Page 2: ...ctrical parts Don t remove motor and circuit board to avoid electric leakage Must use three phase power socket Improper ground wire connection may cause electric shock Safety Attentions 2 The followin...

Page 3: ...ality 2 Energy Recover Function Usually the temperature and humidity difference between indoor air and outdoor air is very large When the indoor is under the comfortable temper ature and humidity it w...

Page 4: ...e machine 2 After startup touch the Mode button to switch mode Auto Manual Timer Sleep PUIE L PUIE M PUIE H Remark when the machine starts default is Auto mode 3 Under Manual mode touch button or to s...

Page 5: ...and save setting automatically After timer setting finished if repress Timer button top right corner of the display shows remaining time for the timer setting at this time it is ok to set the timer ag...

Page 6: ...ht side of the ventilator as showed by the below pic ture it is to filter the large particle in the air Daily maintenance of the OA primary filter use the vacuum cleaner to clean the filter recommende...

Page 7: ...n make self trouble shooting following below chart in case of any failure Phenomenon Possible reasons Solutions The display doesn t start up 1 Loosen or bad contact of power plug 2 Broken of power cab...

Reviews: