Cairox CHRU-L300 Technical Manual Download Page 1

Technical Manual of  

Vertical Energy Recovery Ventilator 

APPLIED TO MODELS 

CHRU

-L300

CHRU-

L600

 

Contents 

A c c e s s o r i e s   L i s t - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 

S a f e t y   A t t e n t i o n s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 

P r o d u c t   I n t r o d u c t i o n s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3 

S p e c i f i c a t i o n s   a n d   O p e r a t i o n   I n s t r u c t i o n s - - - - - - - - - - 4 ~ 5 

O p e r a t i o n   I n s t r u c t i o n s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 ~ 7 

I n s t a l l a t i o n   I n s t r u c t i o n s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8 ~ 9 

M a i n t e n a n c e - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 0 ~ 1 1 

F a i l u r e   D i a g n o s e - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 2 

Contents

Attention 

Please read this 

manual carefully 

before using the 

equipment

Importer:

 

Cairox Bulgaria Ltd.

Sofia 1582, 301 Tzarigradsko chaussee Blvr.

Tel: +359 2 439 55 55

Email: [email protected]

www.cairox.bg

Summary of Contents for CHRU-L300

Page 1: ...n s a n d O p e r a t i o n I n s t r u c t i o n s 4 5 O p e r a t i o n I n s t r u c t i o n s 6 7 I n s t a l l a t i o n I n s t r u c t i o n s 8 9 M a i n t e n a n c e 1 0 1 1 F a i l u r e D...

Page 2: ...ctrical parts Don t remove motor and circuit board to avoid electric leakage Must use three phase power socket Improper ground wire connection may cause electric shock Safety Attentions 2 The followin...

Page 3: ...ality 2 Energy Recover Function Usually the temperature and humidity difference between indoor air and outdoor air is very large When the indoor is under the comfortable temper ature and humidity it w...

Page 4: ...e machine 2 After startup touch the Mode button to switch mode Auto Manual Timer Sleep PUIE L PUIE M PUIE H Remark when the machine starts default is Auto mode 3 Under Manual mode touch button or to s...

Page 5: ...and save setting automatically After timer setting finished if repress Timer button top right corner of the display shows remaining time for the timer setting at this time it is ok to set the timer ag...

Page 6: ...ht side of the ventilator as showed by the below pic ture it is to filter the large particle in the air Daily maintenance of the OA primary filter use the vacuum cleaner to clean the filter recommende...

Page 7: ...n make self trouble shooting following below chart in case of any failure Phenomenon Possible reasons Solutions The display doesn t start up 1 Loosen or bad contact of power plug 2 Broken of power cab...