72
reconnection”, gateway will automatically power down and after a
moment power on again, and dail-up, reconnecting center server till
connect server successfully.
Interval of reconnection
:
Interval time of wireless gateway to reconnect
with center server, the unit is second. When the connection with center
server fails, if reconnect time is less than configured times, it will
reconnect center server within the appointed time.
Interval of keeping alive
:
Interval time of keeping alive data sent
periodically to maintain link. Unit is second. Default is 60s. Interval of
keeping alive time can’t set too small, if so, it will cause flow increasing. It
also can’t be too large, if so, device can be detected after long time
offline. Suggested value is 10S<X<120S
Self-registered packet
:
When DTU establish connection with center
server, DTU will send registration information to center; if registration
packet needs specific definition, please install the specific definition here
Keep alive packet define
:
After DTU connect with wireless network, if
there is no data transmission within a certain time, wireless network will
disconnect with DTU automatically. In order to keep DTU connection with
wireless network, it will send packet to data center from time to time
Option
:
None Function
introduction: don’t send packet
Option
:
Use Default Function introduction: use default 0xFE
Option
:
Self Define Function introduction: Customer define their own
packet according to actual situation
4.6.7 SNMP Configuration
SNMP is Simple Network Management Protocol. If enable this function,
the device can connect with SNMP server, and users can manage and
configure the multi devices with SNMP client, including parameter
configuration of one or more device, upgrading remotely and querying
GPS location information(if GPS is supported), flow information, real-time