Caffini LIBELLULA 2

 

9

 

LIBELLULA  2" 

Shell 

Omala 150 

BP 

Energol GR-XP150 

Esso 

Spartan EP 150 

Mobil oil 

Mobilgear 600 XP150 

Agip 

Blasia 150 

 

Lubricating the gears happens automatically for splashing inside the reducer carter. 

 
 
13.
 MAINTENANCE 

All  maintenance  operations  must  be  carried  out  with  machine  still,  disconnected  from  any  feeders  and 
disconnected from the suction and delivery piping. 
Change the reducer oil after the first 50 hours of functioning by loosening the drain plug in the lower part of 
the reducer. Subsequently, the oil must be changed every 1000 hours of functioning or annually. For synthetic 
type oil, follow the supplier instructions. 
Do not forget to regularly check the oil level through the refuelling plug rod. 
Every three months check the diaphragm and the valves for wear. 
During the winter period with the machine still, protect the pump from freezing; drain any liquids from inside 
the  pump  body  making  them  leak  out  of  the  delivery  valve,  prior  to  tilting  the  same  pump  or  through  the 
pump body drain plus found underneath the same body. 

 

    

MAINTENANCE SHEET

MAINTENANCE SHEET

MAINTENANCE SHEET

MAINTENANCE SHEET    

                             

MAINTENANCE 

                              PROGRAM  

 
 

ITEMS 

B

ef

or

eve

ry 

us

A

ft

er

 e

ve

ry 

us

F

ir

st

 m

ont

or

 20 

hour

E

ve

ry 

m

ont

hs

 or

 

50 

hour

E

ve

ry 

m

ont

hs

 or

 

100 

hour

Y

ea

rl

or

 

300 

hour

Engine oil             - level check 
                             - change 

 X 

 

 

 

 

 

 

 

 

 

                                        - check 

 X 

 

 

 

 

 

Air filter                          - clean 

 

 

 

     X 

 

 

                                        - change 

 

 

 

 

 

    X 

Carburettor tank              - clean 

 

 

 

     X 

 

 

Spark plug                       - clean 

 

 

 

 

 

                                        - change 

 

 

 

 

 

     X 

Minimum                        - check 

 

 

 

 

 

     X 

Valves clearance             - check 

 

 

 

 

 

     X 

Tank and filter                - clean 

 

 

 

 

 

     X 

Petrol pipe                      - check 

 

Every   2 years 

 

 

 

Body pump                     - wash 

 

   X 

 

 

 

 

Pipes and filter               - check 

   X 

 

 

 

 

 

Connecting rod bearing  - check 

 

 

 

 

 

     X 

Reducer oil           - level check 

 

 

 

    X 

 

 

                             - change 

 

 

 

 

 

     X 

In/Out valves        - inspection 

 

 

 

 

 

     X 

Diaphragm           - inspection 

 

 

 

 

 

     X 

Nuts and bolts   - check fastening 

 

 

 

 

 

     X 

 
14. SPARE PARTS 

Summary of Contents for LIBELLULA 2" Series

Page 1: ...EN USE AND MAINTENANCE INSTRUCTIONS SELF PRIMING DIAPHRAGM PUMPS LIBELLULA 2 SERIES...

Page 2: ...e 4 5 USE page 4 6 SOUND LEVEL page 5 7 SAFETY AND ACCIDENT PREVENTION page 5 8 SAFETY STANDARDS page 5 9 HANDLING AND TRANSPORT page 7 10 STORAGE page 7 11 INSTALLATION page 7 12 BEFORE START UP page...

Page 3: ...rial and or series number All our products have a 12 month warranty starting from the commissioning date and however for not more than 18 months from the date of delivery The repairs carried out under...

Page 4: ...t The permanent protection is locked and held in its right position by fastening bolts The machine is provided with lifting hook suitable for handling the pump coupled with the engine supplied by the...

Page 5: ...ON IMPORTANT It is compulsory for the employer to provide I P D Individual Protection Devices and inform staff on their correct use and maintenance IMPORTANT The operator must always observe the presc...

Page 6: ...silencers cylinders or cooling fins when hot as contact can cause burns To avoid certain parts hitting persons in case of machine falling ensure that during the lifting operations no persons are withi...

Page 7: ...eeze during the winter months and damage the system When the liquid is dangerous take all necessary precautions before draining the tank to prevent damages and accidents Periodically start the pump fo...

Page 8: ...l a differential switch with high sensitivity as additional protection against electric shocks in case of insufficient earthing In the three phase version connect the earth wire yellow green of the po...

Page 9: ...nd the valves for wear During the winter period with the machine still protect the pump from freezing drain any liquids from inside the pump body making them leak out of the delivery valve prior to ti...

Page 10: ...inal shot with a torque wrench The mask is reversible sided Body support Disassembly 1 Remove the 4 socket head screws 8x90 6mm Allen key media foot on the shock absorber 2 Place the comfortable bench...

Page 11: ...uce the suction height 2 Restore seal of all gaskets of the piping 3 Remove any blocking bodies inside the pump 4 Fully submerge the suction pipe so it does not suck air 5 Clean the suction filter 6 R...

Page 12: ...lubricated rigid connecting rod Suction ports diameter 2 BSP Delivery ports diameter 2 BSP Total maximum head 15 metres Total maximum suction 6 metres Maximum flow rate 170 l min 10 mc h Priming time...