SERVICE & INSTALLATION MANUAL - Emblem
Brew Group Assembly Sanitizing Treatment
Frequency: quarterly or every 5,000 cycles
Regular sanitation treatments of the brew group assembly prevent residues from affecting
the vacuum in the mechanism and altering the taste of the beverages.
Please refer to the section 7.2 of this manual for sanitizing instructions.
7.8.7 Fans
Frequency: quarterly or as needed
Visually inspect the 2 fans located at the back of the
machine.
1. Turn OFF the unit and unplug it to stop the fan.
2. Remove the back panel.
3. Unplug the fan and remove it to access the fan
blades (2 bolts).
4. Unplug the blower, remove its guard and remove
the fan to access its blades (5 nuts).
5. Wipe the 2 fans clean with a dry disposable towel.
6. Reinstall parts, plug the fans and the machine in,
then turn the brewer back ON.
P
re
v
e
n
ti
v
e Ma
in
te
na
nc
e
Blower