Café

 1.7 Cu. Ft. Convection Over-the-Range 

Microwave Oven

CVM517P4MW2 / CVM517P3MD1 / CVM517P2MS1

© 2019 GE Appliances     PC90238    03/19

DIMENSIONS AND INSTALLATION INFORMATION 

(IN INCHES)

For answers to your Café™ product questions, visit our website at cafeappliances.com.

Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet 
above microwave oven. No additional wiring, venting or cabinet rebuilding necessary in 
many cases. Complete detailed, easy-to-follow installation instructions and convenient 
full-size templates are packed with the microwave oven.

Important Information: When installing the microwave oven over a range, allow  
minimum of 2" from bottom of microwave oven to top of range backguard to  
allow for removal of light covers.

Ventilation Options: The microwave ovens are designed for adaptation to  
the following three types of ventilation: 
-Outside exhaust (vertical – as shown) 
-Outside exhaust (horizontal) 
-Recirculating (non-vented ductless – see Filter Kit drawing)

Installation Information: This information is not intended to be used for installing  
unit described. Before installing, consult installation instructions packed with  
product/kit for current dimensional data.

Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT.  
Read the following carefully.

Exhaust Connection: The hood exhaust has been designed to mate with a standard 
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition 
adaptor must be used. Do not use less than a 6" diameter duct.

Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to 
align exhaust with space between studs, or wall should be prepared at the time it is 
constructed by leaving enough space between the wall studs to accommodate exhaust.

Maximum Duct Length: For satisfactory air movement, the total duct length of  
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.

Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow 
and are equivalent to a section of straight duct which is longer than their actual physical 
size. When calculating the total duct length, add the equivalent length of all transitions 
and adaptors plus the lengths of all straight duct sections. The chart below shows the 
approximate feet of equivalent length of some typical ducts.

105°

Door open

(without obstruction)

24-1/2

"

29-7/8"

16-1/2"

(rear)

15-1/2"

15-3/4"

13"

MAX.

12"

MIN.*

66"

 MIN.

Mounting

height from

floor

Minimum distance from

door hinge side to

adjacent wall should

equal 

1/2"

30"

 MIN.

width 

required

Exhaust outlet

connects to

3-1/4"x10"

 duct

*Maximum depth

with JX15

Bump Out Kit is 

16"

Bump Out Kit

sold separately.

Filler Panel Kits JX36DSS/DDS

When replacing a  36" range hood, this kit fills in the additional width to provide  
a custom built-in appearance. For installation between  cabinets only; not for  
end-of-cabinet installation. Each kit  contains two 3"-wide filler panels.

Filter Kit WB02X11544–Recirculating Charcoal Filter Kit To be used when the 
microwave oven cannot be vented to the outside. 

DUCT

EQUIVALENT FEET 

A.   Rectangular-To-round 

Transition Adaptor

5 ft.

B.  Wall Cap

40 ft.

C.  90° Elbow

10 ft.

D.  45° Elbow

5 ft.

E.  90° Elbow

25 ft.

F.  45° Elbow

5 ft.

G.  Roof Cap

24 ft.

OPTIONAL ACCESSORIES  

(AVAILABLE AT ADDITIONAL COST)

CXOTRHKPMSS  

Brushed Stainless 

1 handle 

(Standard on Matte Black)

CXOTRHKPMBT  

Brushed Black 

1 handle  

CXOTRHKPMCU  

Brushed Copper

1 handle

CXOTRHKPMBZ 

Brushed Bronze 

1 handle 

(Standard on Matte White)

ADDITIONAL ACCESSORIES