5 MAKE ELECTRICAL
CONNECTIONS
WARNING
Switch power off at the service panel
and lock the service disconnecting means to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as
a tag, to the service panel.
Place oven on table or platform even with the cutout
opening. For a steam oven, the platform must
support 170 lbs. (78 kg). Connect the flexible conduit
to the electrical junction box as shown below*.
Position the conduit in such a manner that it will lie
behind the unit in a natural loop when the oven is
installed. You will need to purchase an appropriate
strain relief clamp to complete the connection of the
conduit to the junction box.
* Ovens come equipped with a 40” or 54” long conduit.
If a longer conduit is desired, there may be one
available for your model. To check availability or
order parts, visit
cafeappliances.com.
Junction Box
Conduit
Ground
Red
White
Black
Strain Relief Clamp
(not included) Must Be
Used at Junction Box
Place Oven on a
Support to Assist in
Connecting Conduit
Ground
Wire
6 THREE-CONDUCTOR BRANCH
CIRCUIT CONNECTION
NOTE:
If residence leads are aluminum conductors,
see
WARNING
in Section 4, Electrical Requirements.
When connecting to a three-conductor branch circuit, if
local codes permit:
A.
Connect the oven ground conductor along with the
neutral (white) lead to the branch circuit neutral
(white or gray in color), using a wire nut.
B.
Connect the oven red lead to the branch circuit red
lead and the oven black lead to the branch circuit
black lead in accordance with local codes, using
wire nuts.
C.
Install proper strain relief clamp.
D.
Install junction box cover.
Ground and
neutral wires (white)
Tape or Crimp
Neutral wire
connection
Black
Red
Branch
circuit
Alternate
knockout
Range conduit
snaps into box
Junction Box Cover