Installation Instructions

3   DOOR REMOVAL

NOTE: 

Door removal is not a requirement 

for installation of the product but is an added 
convenience.

To remove the door:

A. Open the oven door as far as it will go.

B. Remove hinge bracket, if equipped, 

from front frame and set aside. 
The hinge bracket must be 
replaced, if equipped, for proper 
door functionality when door is 
reinstalled.

C. Push both hinge locks down toward 

the door frame to the unlocked 
position. This may require a flat-
blade screwdriver. 

DO 

NOT LIFT THE DOOR BY 
THE HANDLE!

D. Place hands on 

both sides of the door 
and close the oven 
door to the removal 
position (approximately 1”–2” [2.5 cm–5.1 cm] from 
the closed position).

E. Lift the door up and out until the hinge arms clear 

the slots. 

NOTE: 

The oven door is very heavy. Be 

sure you have a firm grip before lifting the oven 
door off the hinges. Use caution once the door is 
removed. Do not lay the door on its handle. This 
could cause dents or scratches.

Hinge Bracket

Hinge Slot

Hinge Arm

Hinge Unlocked 
Position

Hinge Clears Slot

4   ELECTRICAL REQUIREMENTS

WARNING

 This appliance must be properly 

grounded.

WARNING

 To prevent fire or shock, do not use 

an extension cord with this appliance.

WARNING

 To prevent shock, remove house 

fuse or open circuit breaker before beginning 
installation.

WARNING

 Improper connection of aluminum 

house wiring to copper leads can result in an 
electrical hazard or fire. Use only connectors designed 
for joining copper to aluminum and follow the 
manufacturer’s recommended procedure closely.

We recommend you have the electrical wiring and 
hookup of your appliance connected by a qualified 
electrician. After installation, have the electrician show 
you how to disconnect power from the appliance.

You must use a single-phase, 120/208 VAC or 
120/240 VAC, 60 Hertz electrical system. If you 
connect to aluminum wiring, properly installed 
connectors approved for use with aluminum wiring 
must be used.

Effective January 1, 1996, the National Electrical 
Code requires that new construction (not existing) 
utilize a four-conductor connection to an electric oven. 
When installing an electric oven in new construction, 
a mobile home, recreational vehicle or an area where 
local codes prohibit grounding through the neutral 
conductor, refer to the section on four-conductor 
branch circuit connections.

Check with your local utilities for electrical codes which 
apply in your area. Failure to wire your oven according 
to governing codes could result in a hazardous 
condition. If there are no local codes, your oven must 
be wired and fused to meet the National Electrical 
Code, NFPA No. 70 – latest edition, available from the 
National Fire Protection Association.

Summary of Contents for CMB903M

Page 1: ...ces com Installation Instructions TM Contents Safety Information 2 Installation Instructions Step 1 Remove Packaging and Parts 3 Step 2 Prepare the Opening 3 Step 3 Door Removal 9 Step 4 Electrical Re...

Page 2: ...lectric wall ovens must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products FOR YOUR SAFETY WARNING Before beginning the installation swit...

Page 3: ...be installed side by side below a countertop or below specified cooktops See the label on the outside of the oven for approved models IMPORTANT Always refer to individual installation instructions pac...

Page 4: ...bottom 3 4 1 9 cm H Junction Box Location see detail right side preferred Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions Cutout observe...

Page 5: ...observe all dimensions and requirements IMPORTANT Maintain a minimum distance of 22 55 9 cm 23 58 4 min for dropbox models from the top surface of the countertop to the steam oven platform to ensure t...

Page 6: ...pecific installation requirements 2 D CUTOUT FOR STEAM OVEN OVER A WALL OVEN I RX DUH UHSODFLQJ DQ HOHFWULF GRXEOH RYHQ ZLWK WKH combined installation of a built in steam oven and a single oven use th...

Page 7: ...180 pounds 2 F CUTOUT FOR STEAM OVEN UNDER ANOTHER BUILT IN STEAM OVEN BUILT IN SPEEDCOOK OVEN If you are mounting a Built In Steam Oven under a Built In SpeedCook Oven or another Built In Steam Oven...

Page 8: ...cabinet floor between the side cleats push it all the way back against cabinet wall and make sure its front face aligns with the front faces of the side cleats 1 1 2 gap from the front cabinet face A...

Page 9: ...use fuse or open circuit breaker before beginning installation WARNING Improper connection of aluminum house wiring to copper leads can result in an electrical hazard or fire Use only connectors desig...

Page 10: ...NECTIONS WARNING Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be lock...

Page 11: ...s When connecting to a four conductor branch circuit if local codes permit A Free the neutral white lead from being restrained to any other wires If necessary cut the neutral white lead and then re st...

Page 12: ...g screws and drive the screws into the side flanges It is recommended that the screws be hand tightened Installation Instructions 8 SLIDE OVEN INTO OPENING A Loop do not tie a 36 91 cm string around t...

Page 13: ...Hinge Notch Hinge Bracket 11 FINAL INSTALLATION CHECKLIST KHFN WR PDNH VXUH WKH FLUFXLW EUHDNHU LV FORVHG RESET or the circuit fuses are replaced H VXUH SRZHU LV LQ VHUYLFH WR WKH EXLOGLQJ KHFN WKDW D...

Page 14: ...escribed in this book safety glasses or goggles should be worn NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to ch...

Page 15: ...Paso 2 Prepare la Abertura 3 Paso 3 Retiro de la Puerta 9 Paso 4 Requisitos El ctricos 9 Paso 5 Realice las Conexiones El ctricas 10 Paso 6 Conexi n del Circuito de Empalmes de Tres Conductores 11 Pas...

Page 16: ...contar con cableado de conexi n permanente cableado directo dentro de una caja de conexiones aprobada En estos productos NO se permite la conexi n del tipo enchufe y recept culo PARA SU SEGURIDAD ADVE...

Page 17: ...e otro horno de vapor o un horno Speedcook El horno a vapor tambi n puede ser instalado uno al lado del otro debajo de una mesada o debajo de superficies de cocci n espec ficas Para conocer los modelo...

Page 18: ...onexiones Consulte el detalle sobre preferencias de ubicaci n del lado derecho Se refiere al espacio m nimo requerido para la instalaci n del horno de pared y no refleja las dimensiones reales del pro...

Page 19: ...6 5 kg PARA HORNOS A VAPOR 22 55 9 cm M n 23 58 4 cm Mi with Dropbox Models above Platform Support 22 55 9 cm m n 23 58 4 cm m n en Modelos con Buz n sobre la plataforma de soporte Abertura cumpla con...

Page 20: ...stalaci n Bloque anti volcaduras contra la pared trasera seg n requisito del caj n calentador Seg n los requisitos del caj n calentador 1 5 8 4 2 cm Min 2 D ESPACIO LIBRE PARA HORNOS A VAPOR SOBRE UN...

Page 21: ...as 2 F ESPACIO LIBRE PARA EL HORNO DEBAJO DE OTRO HORNO A VAPOR INCORPORADO HORNO SPEEDCOOK INCORPORADO Si montar un Horno a Vapor Incorporado debajo de un Horno SpeedCook Incorporado u otro Horno a V...

Page 22: ...etamente hacia atr s contra la pared del gabinete y aseg rese de que su cara frontal se alinee con las caras frontales de los ristreles laterales brecha de 1 1 2 desde la cara del gabinete frontal 2 H...

Page 23: ...ERTENCIA Para prevenir una descarga el ctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n ADVERTENCIA Una conexi n inadecuada de cableado dom stico de aluminio...

Page 24: ...Desconecte la energ a del panel de servicio y bloquee los medios de desconexi n para evitar el accionamiento de la energ a de manera accidental Cuando los medios de desconexi n de servicio no pueden b...

Page 25: ...ado de cuatro conductores si lo permiten los c digos locales A Evite que el conductor neutro blanco quede enredado con cualquier otro cable De ser necesario corte el conductor neutro blanco y luego vu...

Page 26: ...incluidas en los tornillos de montaje y coloque los tornillos en las leng etas laterales Se recomienda ajustar los tornillos de forma manual 8 DESLICE EL HORNO DENTRO DE LA ABERTURA A Enrosque no ate...

Page 27: ...sagra 11 LISTA DE CONTROL FINAL DE LA INSTALACI N 9HULILTXH TXH HO LQWHUUXSWRU GH FLUFXLWRV VH HQFXHQWUH cerrado RESET o que los fusibles del circuito se hayan reemplazado VHJ UHVH GH TXH KD D VXPLQLV...

Page 28: ...scriptas en este libro se deber n usar anteojos o gafas de seguridad NOTA Monogram Appliances se esfuerza de forma constante para mejorar sus productos Por lo tanto los materiales el aspecto y las esp...

Reviews: