background image

2

NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.

TABLE OF CONTENTS

1.0         PACKING LIST

 

2.0         
3.0         INTRODUCTION

                 3.1  DIMENSIONS
                 3.2  LISTING APPROVALS
                 3.3  GENERAL INSTRUCTIONS

4.0         PLACING APPLIANCE

                 4.1  UNPACKING AND TESTING APPLIANCE
                 4.2  GROUNDING APPLIANCE

5.0         INSTALLATION

                 5.1  WALL-MOUNT INSTALLATION
                 5.2  RECESSED INSTALLATION
                 5.3  FREE STANDING INSTALLATION (OPTION)

6.0         FINISHING

                 6.1  GLASS DOOR REMOVAL
                 6.2  MEDIA BED KITS INSTALLATION
                        

6.2.1 6 INTERCHANGEABLE MEDIA BED KITS OPTIONS

                 6.3  GLASS DOOR INSTALLATION

7.0         OPERATING INSTRUCTIONS

                 7.1  MAIN POWER BUTTON
                 7.2  REMOTE CONTROL
                        

7.2.1 BATTERY INSTALLATION

                        

7.2.2 REMOTE OPERATION

                 7.3  PANEL CONTROL

8.0         

                 8.1  PARTIALLY REFLECTIVE GLASS CLEANING
                 8.2  GLASS DOOR CLEANING
                 8.3  SERVICING

9.0         REPLACEMENT PARTS
10.0       WARRANTY

WELCOME & CONGRATULATIONS

MAINTENANCE

3
4
4

5
5
6

7

7
7

8

9
10
10

11

11
12

12

13

13

13
14

14
14

15

16

16
16
16

17
18

Summary of Contents for CHFP-50A

Page 1: ...MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE SAFETY INFORMATION WARNING Phone 626 328 6324 Fax...

Page 2: ...5 3 FREE STANDING INSTALLATION OPTION 6 0 FINISHING 6 1 GLASS DOOR REMOVAL 6 2 MEDIA BED KITS INSTALLATION 6 2 1 6 INTERCHANGEABLE MEDIA BED KITS OPTIONS 6 3 GLASS DOOR INSTALLATION 7 0 OPERATING INS...

Page 3: ...tion Quantity 1 Electric fireplace 1 pc 2 Installation and operating instructions 1 pc 3 Remote control battery included 1 pc 4 Media bed kits falling stars 2 boxes 5 Wall mount bracket 1 pc 6 Wall an...

Page 4: ...cracked or broken Replacement of the glass should be done by a licensed or qualifed service person Do not strike or slam shut the appliance glass door Keep the packaging material out of reach of chil...

Page 5: ...s or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition in the United States or the Canadian Electric Code ETL in Canada FRONT VIEW SIDE VIEW 22 3 4 578mm 6 3 4 171m...

Page 6: ...INSIDE DO NOT USE DAMAGED ELECTRICAL CORDS SERVICING SHOULD BE DONE ONLY WHEN THE APPLIANCE IS DISCONNECTED FROM THE POWER SUPPLY CIRCUIT TO PREVENT ELECTRIC SHOCK MATCH THE WIDE BLADE OF PLUG TO WID...

Page 7: ...APTER GROUNDING PIN COVER OF GROUNDED OUTLET BOX C B This appliance is for use on 110 Volts The cord has a plug as shown in A An adapter as shown in is available C for connecting three blade grounding...

Page 8: ...INSULATION AGAINST THE APPLIANCE THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC...

Page 9: ...upplied screws This bracket MUST have the hooks facing upward and be leveled NOTE It is strongly recommended that the mounting bracket be screwed into the wall studs where possible If the wall studs c...

Page 10: ...glass door to its place A Leave a frame in the wall the size is W44 1 2 H22 3 4 D4 B Have two people put the box into the wall and fix the box to the wall with self tapping screws C Put the hooks on...

Page 11: ...OORS OR ACCESS FOR SERVICE OBSERVE A B To d Plastic Connector Plastic Connector C Remove the glass door from appliance Two people to hold the glass door and lift the door until it s out of the holes i...

Page 12: ...ace media bed kits into the bottom tray on the front of the appliance as illustrated Apply an even layer from side to side Model CHFP 50A Media bed kits Morocco Dream Winter Flakes Thahiti Getaway Fal...

Page 13: ...glass door for stability ensuring the hooks will not break free from the holes 7 1 MAIN POWER BUTTON Once the appliance has been plugged into a grounded electrical outlet it is ready to operate The Ma...

Page 14: ...1 to 4 when changing colors When you press the button for 3 seconds until you hear a beep the indicator will show digital 0 the flame color and brightness will be changed automatically E To change fla...

Page 15: ...nges from 1 to 8 hours which will be shown on the indicator from 1H to 8H Timer is turned off when the indicator shows 0H If the appliance is restarted timer also needs to be reset again NOTE This rem...

Page 16: ...in the factory during the assembly operation During shipment installation handling etc the partially reflective glass may collect dust particles these can be removed by dusting lightly with a clean dr...

Page 17: ...WER BUTTON REFLECTOR 11 12 CHP 001 CHP 002 CHP 003 CHP 004 CHP 005 CHP 006 CHP 007 CHP 008 CHP 009 CHP 010 CHP 011 CHP 012 1 2 3 4 5 6 7 8 9 10 11 12 13 13 CHP 013 STAND 9 0 REPLACEMENT PARTS 626 328...

Page 18: ...ect any product or part thereof prior to honoring any warranty claim All parts replaced under the Limited Warranty Policy are subject to a single claim All parts replaced under the warranty will be co...

Reviews: