NGPS
–
User’s Manual
90
SETFLOAT Command
The
SETFLOAT
command can be used to set the system in floating mode.
The two commands are
SETFLOAT:F
to set the unit in floating mode or
SETFLOAT:N
to set the unit as grounded. Earth fuse must be disconnected to operate
the unit in floating mode. Refer to section 1.8.2
Replies from the NGPS to a
SETFLOAT
are in the form “
#AK\r\n
” –
when the
command is correctly executed -
or “
#NAK:xx\r\n
”, when the command cannot be
executed (“
xx
” is the error code).
Replies to command
SETFLOAT:?
will be
“
#F\r\n
”
or
“
#N\r\n
”
respectively
if the module current setting is in floating mode or standard one.
Example:
SETFLOAT example:
SETFLOAT:F
\r\n
#AK
\r\n
When the unit operates in Floating Mode it is unable to detect earth faults
of the output conductors. Thus, a first fault can remain undetected, also
for long time. In this condition occurrence of a second earth fault can be
dangerous for equipment and goods and can, in extreme cases, also trigger
fire. Use of Floating Mode shall be reserved only for system already
equipped with an external earth fault detection system.