3.3

 

Injury Precautions 

 
 

This  section  contains  the  fundamental  safety  rules  for  the  installation  and 

operation of the system in order to avoid injuries. 
 

3.3.1

 

Caution 

 

The following safety precautions must be observed during all phases of operation, 

service and repair of this equipment. Failure to comply with the safety precautions or 
warnings  in  this  document  violates  safety  standards  of  design,  manufacture  and 
intended use of this equipment and may impair the built-in protections within.  

 
CAEN  ELS  d.o.o.  shall  not  be  liable  for  user’s  failure  to  comply  with  these 

requirements. 

 
To avoid electrical shock or fire hazard, do not apply a voltage to a load that is 

outside the range specified for that load.  

 
Do Not Operate Without Covers.  

 

To avoid electric shock or fire hazard, do not operate this product with covers or 

panels removed.  
 

Do Not Operate in Wet/Damp Conditions.  

 

To avoid electrical shock, do not operate this product in wet or damp conditions.  

 

Do Not Operate in an Explosive Atmosphere.  

 

To  avoid  injury  or  fire  hazard,  do  not  operate  this  product  in  an  explosive 

atmosphere.  

 
Do Not Operate With Suspected Failures.  

 

If you suspect there is damage to this product, have it inspected by qualified service 

personnel. 

 
 

3.4

 

Input Ratings 

 

Do not use DC supply which exceeds the input voltage rating of this instrument. 

MTCA standards requires a fixed DC voltage source of +12V for bulk power and +3.3V 
for management power, refer to the relevant standard for further informations.  

 
For  safety  reasons,  the  supply  voltage  fluctuations  should  not  exceed  above 

voltage range. 

 
 

Summary of Contents for HV-PANDA

Page 1: ...AMC HV PANDA User s Manual 3 HV PANDA HV Positive And Negative Double width AMC User s Manual All Rights Reserved CAEN ELS s r l Rev 1 1 May 2018 AMC ADVANCED MEZZANINE CARD...

Page 2: ...AMC HV PANDA User s Manual 2 CAEN ELS s r l Via Vetraia 11 55049 Viareggio LU Italy Mail info caenels com Web www caenels com...

Page 3: ...16 3 4 INPUT RATINGS 16 3 5 OUTPUT CONNECTORS 17 3 6 LIVE CIRCUITS 17 3 7 PART REPLACEMENT AND MODIFICATIONS 17 3 8 INSTALLATION INSTRUCTIONS 17 3 8 1 Installation in a MTCA 4 chassis 17 3 8 2 Instal...

Page 4: ...HV PANDA User s Manual 4 Document Revisions Document Revision Date Comment 0 1 January 28th 2015 First Release 1 0 September 20th 2015 Sections added and modifications 1 1 May 3rd 2018 Typo errors fix...

Page 5: ...any part of the instrument WARNING Do NOT open the boxes CAEN ELS s r l declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the...

Page 6: ...ged Before you use the device inspect the instrument for possible cracks or breaks before each use Do not operate the device around explosives gas vapor or dust Always use the device with the cables p...

Page 7: ...l environmental requirements for a correct operation of the instrument Environmental Conditions Requirements Operating Temperature 0 C to 50 C Operating Humidity 30 to 85 RH non condensing Storage Tem...

Page 8: ...round return that is allowed to float up to 120 V factory limited to 15 V for safety reasons Each channel has an independent dry interlock available through a connector on the AMC front panel The indi...

Page 9: ...ceivers to allow the user to provide triggering signals for HV channels or RTM synchronization The micro USB port on the front panel provides a means to slowly communicate with both FPGA and AMC Modul...

Page 10: ...igure 2 AMC HV PANDA Component side 2 Figure 3 AMC HV PANDA front view The AMC HV PANDA can be subdivided into the following building blocks the HV channel the HV digital and analog control logic and...

Page 11: ...control electronics that resides on the AMC board The HV control logic reads relevant informations from the modules and takes immediate actions according to informations provided by the AMC digital l...

Page 12: ...RTM connection recommendations The Module Management Controller MMC is fully compliant with PICMG AMC 0 R2 0 specification with the additional requirements as per PICMG Specification MTCA 4 Rev 1 0 a...

Page 13: ...g the system boards by means of the MCMC controller on the IPMB x busses providing connectivity options between AMCs on multiple Ports providing clock distribution PM Power Module Board responsible fo...

Page 14: ...f hot swap and communication status LED 1 red color provides indication of faults LED 2 green color indicates in service status Logic GND The reference potential for logic signals and power levels She...

Page 15: ...ble as you read the marking WARNING indicates an injury hazard not immediately accessible as you read the marking CAUTION indicates a hazard to property including the product 3 2 Initial Inspection Pr...

Page 16: ...side the range specified for that load Do Not Operate Without Covers To avoid electric shock or fire hazard do not operate this product with covers or panels removed Do Not Operate in Wet Damp Conditi...

Page 17: ...rt the PCI e link on port 4 and optionally a Gigabit Ethernet link on port 0 Follow these instructions in order to correctly install the AMC HV PANDA board in a Double width capable MTCA chassis or AT...

Page 18: ...nto the MTCA chassis the extended face plate of the AMC front panel shall be almost in contact with the sub rack retention interface and allow the front panel screws to be locked to the chassis Do not...

Page 19: ...easons the MTCA standard requires the presence of two separate ground connections a Logic GND that is the reference potential for the Payload Power and the Management Power and a Chassis GND that is c...

Page 20: ...AMC HV PANDA User s Manual 20 The return current path is always established through the cable shield HV GNDs Logic GND Chassis GND Figure 5 Grounding Connections...

Page 21: ...prietary user space driver provided in the User s CD The HV Panda can also be operated using the DESY pcieuni driver in conjunction with the panda map file that is provided in appendix and also in the...

Page 22: ...own the channel The Leds on the bottom of the GUI provide visual indication of the status of the channel and in the case of the overcurrent are redundant to what is provided by the actual leds located...

Page 23: ...ANDA 4 channel HV Full size AMC Board 6kV 6W per channel Negative polarity HVPANDA4KPXA HV PANDA 4 channel HV Full size AMC Board 4kV 7W per channel Positive polarity HVPANDA4KNXA HV PANDA 4 channel H...

Page 24: ...Board Size Double Width Full Size RTM Supported Type According to DESY D1 1 specification Number of HV Channels 4 HV Channels Connectors SHV Table 1 General information for the AMC HV PANDA 6 1 Electr...

Page 25: ...ution 0 01 Ramp Speed From 1 to 500 V s Ramp Speed Step Size 1 V s Stand by Voltage Set Resolution 1 of FS Current Limit Value Accuracy 4 of FS Output Current Threshold Behaviour switch off current so...

Page 26: ...TCA Enhancement for Rear I O and Precision Timing The board is a double width full size AMC card with front panel SHV connectors The mechanical dimensions of the AMC board can be found in the followin...

Page 27: ...0000004 0x00000000 32 0 1 CH3_V_MON 0x00000001 0x00000148 0x00000004 0x00000000 32 0 1 CH3_I_MON 0x00000001 0x0000014C 0x00000004 0x00000000 32 0 1 CH3_STATUS 0x00000001 0x00000150 0x00000004 0x000000...