5

PM2.5 Indicator

The PM2.5 indicator in this product measures and displays the 
number of PM2.5 microscopic particulates (a rough indication) 
suspended in the air using a simple method.

Note

 This model uses different measuring methods compared to 

government agencies. The displayed particulate concentration may 
differ from concentrations determined using those methods.

The PM2.5 indicator should only be used as a rough estimate.

 In automatic mode, the unit operates in accordance with the overall 

condition of dust and odor without regard to the PM2.5 reading.

Photocatalytic Lamp

The blue activated carbon in the deodorizing/dust collecting/
anti-bacterial filter does not use the conventional ultraviolet ray 
reaction type, but instead uses a new type of photocatalytic 
technology that reacts with visible light.
The lamp in the product uses a long life blue LED, and does 
not have any effects on eyes or the human body in the way 
ultraviolet rays do, but since the light is strong, when performing 
maintenance such as removing the filter to replace it, unplug the 
power plug and avoid looking directly into the light.
(The photocatalytic lamp will turn off if the deodorizing/dust 
collecting/anti-bacterial filter is removed.)

Odor and Dust Monitor

The odor and dust sensors detect pollutants in the air and 
indicates the air environment in the room with the colors blue, 
yellow, and red.

Odor and dust monitor  Air environment of room

 

Blue 

  Clean

 Yellow 

  Slightly 

polluted

 Red 

  Polluted

Odor and dust sensors

  

Detected objects

Odor sensor

The odor sensor is placed inside 

the unit.

Detects cigarette, pet, and cos-
metic odors.

Dust sensor

The dust sensor is placed on the 

backside of the unit.

Detects house dust (dust, pol-
len, etc.) and cigarette smoke.

Note

 The odor and dust sensors may react to changes in temperature and 

humidity.

 The odor sensor may not react depending on the odor components.

 For the first five minutes after turning the power on, the sensors are 

initializing and the unit cannot indicate the exact air condition.

Illumination Intensity Sensor

Detects ambient brightness. The glowing indicators dim when 
surroundings become dark. They increase brightness when 
surroundings become bright.

Summary of Contents for AP-C710S

Page 1: ...Table of Contents 1 Safety Precautions 3 Operating Precautions 3 Installing the Unit 4 Parts and Functions 6 Installing the Deodorizing Dust Collecting Anti Bacterial Filter 7 How to Operate 8 Mainten...

Page 2: ...rvice center Do not use the unit in the following locations In areas with flammable gas or places with metal dust It may lead to the gas catching on fire igniting or fuming due to dust being sucked in...

Page 3: ...in the outlet may cause electric shock or injury Do not sit or stand on the unit Falling down from the unit or toppling may cause injury or malfunction Do not put the unit in unstable locations If th...

Page 4: ...or malfunction of the unit Do not use the unit near a TV or radio It may cause distortion of video images or noise Place the unit at least 1m away from a TV or radio Also using the same wall outlet as...

Page 5: ...culates Cover stopper ones on the left and right side Odor and dust monitor indicates the room air quality in blue yellow and red page 5 Control panel page 7 Handle Ones on the left and right side Use...

Page 6: ...ng maintenance such as removing the filter to replace it unplug the power plug and avoid looking directly into the light The photocatalytic lamp will turn off if the deodorizing dust collecting anti b...

Page 7: ...e unit Align the on the filters with the on the unit as shown in the figure below then insert the filters all the way to the bottom of the unit Installing the Deodorizing Dust Collecting Anti Bacteria...

Page 8: ...light up then turn off Press the power button After it beeps all of the buttons on the control panel along with the automatic indicator odor and dust monitor and the air inlet lamps will light up If...

Page 9: ...from the unit with a soft cloth Remove dust from the air inlet and air outlet with a vacuum cleaner or use a soft cloth to wipe it off When it is extremely dirty use a cloth with watered down neutral...

Page 10: ...sensor Air outlet Air inlet Use a dry cotton swab to wipe the moisture on the sensor air inlet and air outlet Close the dust sensor cover 1 2 3 4 5 1 2 3 Install new filters See Installing the Deodor...

Page 11: ...llecting anti bacterial filter is installed properly and firmly close the top cover 6 The odor and dust monitor remains red even though the air is not dirty The dust and odor sensors may react to chan...

Page 12: ...oes not change in accordance with the indications of the odor and dust monitor The operation does not stop even though the air is clean The unit will continue to operate with a low air volume even if...

Page 13: ...h 423 Depth 297 Height 714 including protrusions Weight kg 18 including filters Power cord length m 1 8 Accessories Instruction manual warranty card deodorizing dust collecting anti bacterial filter 2...