In case of an abnormality or malfunction, immediately 
stop its operation and unplug the power plug.

If you continue operations during a malfunction, it may lead 
to breakdown, electric shock, fuming, or fire.  
<Examples of Malfunction or Breakdown>

 

After the filter or pre-filter is replaced, the unit does not start 

even after pressing the power button.

Electric current is sporadic when moving the cord.

 It vibrates or makes an unusual sound during operations. 

 The unit, power plug, or cord is abnormally hot.

 It smells like something is burning.

Make sure that pets do not urinate on the unit or bite 
the power cord.

It may lead to electric shock or a fire.
If one of the above situations occur, please consult a 
dealer or your nearest customer service center.

Plug the power plug in all the way.

If it is not plugged in all the way, it may cause electric 
shock or fire.

 

Do not use damaged power cords or power plugs, or wall 

outlets that are loose and do not hold the plug.

Regularly wipe dust from the power plug with a dry 
cloth.

If dust builds up, it can lead to insulation failure from 
humidity, etc. and may cause fire.

 

When not in use for a long period of time, remove the power 

plug from the outlet.

During cleaning, inspection, and moving, make sure to 
stop operation and unplug the power plug.

Leaving the power plug in the outlet may cause electric 
shock or injury.

Do not sit or stand on the unit.

Falling down from the unit or toppling may cause injury or 
malfunction.

Do not put the unit in unstable locations.

If the unit falls over, it may cause an electric shock and lead 
to injury or damage.

Do not block the air inlet or air outlet with obejects such 
as laundry, cloth, curtains, etc.

Poor air circulation may lead to overheating or fire.

After maintenance, wipe off the water thoroughly and 
dry the unit. Do not use it when wet.

It may lead to electric shock or injury.

Do not use chlorinated or acid detergents for cleaning.

The detergent may produce toxic gas that is harmful to your 
health.

Do not wipe the unit with benzine or thinner or spray 
with insecticide.

It may lead to cracks, electric shock, or fire.

Do not operate the unit when fumigating for pests.

It may cause accumulated pharmaceutical ingredients 
to emit when using the unit later, which is harmful to your 
health.

 

Prohibited

Periodically open windows to ventilate the room when 
using the unit with a combustion appliance at the same 
time.

This unit does not have a function to eliminate carbon 
monoxide.
If air ventilation is insufficient, it may lead to carbon 
monoxide poisoning.

 

Required

Do not put your fingers or rod-shaped objects into the 
air inlet or outlet.

It may lead to electric shock, damage, or injury.

 

Caution

Summary of Contents for AP-C310

Page 1: ...Table of Contents 1 Safety Precautions 3 Operating Precautions 3 Installing the Unit 4 Parts and Functions 6 Installing the Deodorizing Dust Collecting Anti Bacterial Filter 7 How to Operate 8 Maintenance 10 Troubleshooting 12 Specifications ...

Page 2: ......

Page 3: ...ervice center Do not use the unit in the following locations In areas with flammable gas or places with metal dust It may lead to the gas catching on fire igniting or fuming due to dust being sucked into the unit In bathrooms or other wet areas or areas with high temperature and humidity It may lead to fire or electric shock due to voltage leakage In areas with oil components such as machine oil o...

Page 4: ...e sure to stop operation and unplug the power plug Leaving the power plug in the outlet may cause electric shock or injury Do not sit or stand on the unit Falling down from the unit or toppling may cause injury or malfunction Do not put the unit in unstable locations If the unit falls over it may cause an electric shock and lead to injury or damage Do not block the air inlet or air outlet with obe...

Page 5: ...ting fan in the kitchen This may remarkably lower the lifespan of the filter or lead to the unit becoming deformed Do not place the unit in direct sunlight or directly in the path of the air conditioner or heater s airflow It may cause deformation discoloration or malfunction of the unit Do not use the unit near a TV or radio It may cause distortion of video images or noise Place the unit at least...

Page 6: ... button ones on each side Air inlet ones on each side Top Cover Ribbon Dust sensor page 5 Power cord Pre filter page 8 Photocatalytic lamp inside the unit page 5 Handle Ones on each side Use when lifting the unit Odor sensor page 5 Air inlet lamp inside the unit page 7 Control panel page 7 Odor and dust monitor indicates the room air quality in blue yellow and red page 5 Illumination intensity sen...

Page 7: ... pollutants in the air and indicates the air environment in the room with the colors blue yellow and red Odor and dust monitor Air environment of room Blue Clean Yellow Slightly polluted Red Polluted Odor and dust sensors Detected objects Odor sensor Detects cigarette pet and cos metic odors Dust sensor Detects house dust dust pol len etc and cigarette smoke Note The odor and dust sensors may reac...

Page 8: ...e unit a Place the filter down to the bottom of the unit with its side with the ribbon facing the front of the unit b Lay the filter towards the rear of the unit Installing the Deodorizing Dust Collecting Anti Bacterial Filter 1 2 Close the top cover 3 Note If the filter is in backwards photocatalyst cleaning will not be effective Note If the top cover does not shut properly make sure the filter i...

Page 9: ...high air volume setting for 2 hours then changes to automatic mode How to Operate Changing the Air Volume Press the air volume button Air volume and operation mode cannot be configured simultaneously Each time the air volume button is pressed it makes a beeping sound and the air volume mode changes The indicator of the selected air volume will light up Operation continues with the selected air vol...

Page 10: ...ause damage or warp the unit Wipe dust from the unit with a soft cloth Remove dust from the air inlet and air outlet with a vacuum cleaner or use a soft cloth to wipe it off When it is extremely dirty use a cloth with watered down neutral detergent on it and wipe the filth off 1 2 Remove dust with a vacuum cleaner or dry thoroughly after washing out dust with water Attach the pre filters 1 2 3 Rem...

Page 11: ...ng anti bacterial filter cannot be washed with water Replace it regularly The timing to change the deodorizing dust collecting anti bacterial filter depends on the environment in which the unit is used but generally replace it every 6 12 months 1 1 on page 12 When the filter needs to be replaced the filter replacement indicator will light up Install a new filter See Installing the Deodorizing Dust...

Page 12: ...al filter is installed properly and firmly close the top cover 6 The odor and dust monitor remains red even though the air is not dirty The dust and odor sensors may react to changes in temperature and humidity or gas from sprays and the like Wait a few minutes and make sure the odor and dust monitor changes to yellow or blue 5 Is the dust sensor dirty Clean and remove dirt from the dust sensor 9 ...

Page 13: ...ther than automatic mode In the operation modes other than the automatic mode the air volume does not change in accordance with the indications of the odor and dust monitor The operation does not stop even though the air is clean The unit will continue to operate with a low air volume even if the room is clean The unit smell is unpleasant Is the air inlet air outlet or the pre filter dirty Clean t...

Page 14: ...m Width 350 x Depth 230 x Height 580 including protrusions Weight kg 9 7 including filter Power cord length m 1 8 Accessories Instruction manual warranty card deodorizing dust collecting anti bacterial filter 2 Filter Start Date label 2 Model name For AP C300 series Exterior dimensions mm 295x60x270 1 Calculated based on the test method of the JEM1467 in the Standards of the Japan Electrical Manuf...

Page 15: ......

Page 16: ...JA 00020 0101 http en cado co jp ...

Reviews: