Cadet The Perfectoe UC072 Owner'S Manual Download Page 6

cadetheat.com    Tel: 360-693-2505    PO Box 1675   Vancouver, WA    98668-1675

El Calentador Perfectoe

Manual del Propietario

Beneficios En Las Que Puede Confiar

CONSERVE ESTAS INSTRUCCIONES

14½”

36.83

3½”

8.9

18”

45.7

8¼”

21

8¼”

21

Rejilla Frente

Cámara de pared superior

Cámara de 

pared costado

 .375”

.952

Rejilla costado

17”

43.18

3½”

8.89

Grill Front

17”

43.18

3½”

8.89

Grill Front

•  Diseño delgado para brindar comodidad y ahorrar 

espacio en:     

   Zonas bajo los gabinetes de cocina y baño
   Vehículos recreativos
   Huecos de escaleras
   Hogares Chimenea 

•  Seguro para usted y su familia

 Tranquilidad gracias a la función de apagado    

 automático por alta temperatura  

•  Componentes con sentido común diseñados pen-

sando en usted

 1. SIN bordes filosos

 2. Resistentes a la corrosión 

 3. Elemento resistente y confiable para brindar  

    calor instantáneo
 4. Fácil de instalar

•  Su calentador Cadet ha sido completamente 

probado y cuenta con una 

garantía extendida de 

2 años

(1) 

Termostato estándar incorporado de un solo polo y sin posición de apagado 

(OFF)

(2)

 Los modelos de 240 voltios pueden usarse a 208 voltios. El vatiaje es igual al 

75% de la potencia nominal de 240 v.

(3)

 Para instalaciones a más de 7000 pies, el vatiaje más alto recomendado es de 

750 vatios.

Nota: Kits del termostato opcionales se venden por separado

HERRAMIENTAS NECESARIAS:

• Destornillador Phillips

• Destornillador plano

• Pelacables

• Cuchillo multiuso

• (4) tornillos de 1½” para madera

• Conectores de alambre aislados

• (1) conector de alivio de tensión

Modelos Perfectoe

Voltaje 

Línea

Modelo sin 

Termostato

Modelo con 

Termostato 

(1)

Vatios

Amps

240 

(2)

UC072

750

3.13

UC102 

(3)

1000

4.17

120

UC051

500

4.17

UC101 

(3)

UC101T 

(3)

1000

8.33

http://www.cadetheat.com/wall-heaters/perfectoe

Página 6

Modelos Perfectoe con Termostato

*No requieren termostato mural

Modelos Perfectoe sin Termostato

*Requieren termostato mural

Etiqueta 

Calificación

Botón de límite de 

Reglaje Manual

Termostato Incorporado

Summary of Contents for The Perfectoe UC072

Page 1: ...been thoroughly tested and is guaranteed with a 2 year extended warranty 1 Standard built in thermostat is single pole and has no OFF position 2 240 volt models can be used at 208 volts Wattage equals 75 of 240v rated wattage 3 For installations above 7000 feet highest wattage recommended is 750 watts Note Optional built in thermostat kits sold separately TOOLS REQUIRED Phillips Screwdriver Straig...

Page 2: ...6 To disconnect heater turn controls to off and turn off power to heater circuit at main disconnect panel 7 WARNING Risk of Electrical Shock Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater 8 WARNING Risk of Fire To prevent a possible fire do not block air intakes or exhaust in any manner 9 WARNING F...

Page 3: ...icated on the lid WARNING Vinyl floor manufacturers warn that some vinyl may discolor from temperatures in excess of 110 F See your vinyl floor manufacturer for temperature specifications for your vinyl floor covering CONTROLS A thermostat is required A Cadet electronic thermostat is recommended for ultimate control and comfort Optional single or double pole field mount thermostat kits are also av...

Page 4: ...D THE UNDERLYING WARRANTIES REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES 8 These warranties give you specific legal rights and you may also have other rights which vary from state to state Cadet nei ther assumes nor authorizes anyone to assume for it any other obligation or liability in connection with its products other than as set out herein If you believ...

Page 5: ...rates but does not discharge warm air 1 Insufficient element temperature 2 Incorrect supply voltage 3 Element has failed 1 Allow a few moments for element to reach operating temperature 2 Verify that supply voltage matches the heater rating 3 Replace element Heater will not shut off 1 Heat loss from room is greater than heater capacity 2 Defective thermostat 3 Thermostat wired incorrectly to heate...

Page 6: ...ha sido completamente probado y cuenta con una garantía extendida de 2 años 1 Termostato estándar incorporado de un solo polo y sin posición de apagado OFF 2 Los modelos de 240 voltios pueden usarse a 208 voltios El vatiaje es igual al 75 de la potencia nominal de 240 v 3 Para instalaciones a más de 7000 pies el vatiaje más alto recomendado es de 750 vatios Nota Kits del termostato opcionales se v...

Page 7: ...rocución No opere ningún calentador después de una avería Desconecte la alimentación en el panel de servicio y pida a un técnico electricista calificado que lo revise antes de volver a usarlo 5 ADVERTENCIA No lo use a la intemperie 6 Para desconectarlo ponga los controles en OFF y apague la alimentación del circuito del calentador en el panel de desconexión principal 7 ADVERTENCIA Riesgo de electr...

Page 8: ...gura 2 Empalme cada alambre del suministro a un alambre del calenta dor usando conectores de cables Nota Todas las conexiones de alambres deben hacerse dentro del calentador Vuelva a conectar la electricidad en el tablero del panel eléctrico cortacircuito o caja de fusibles Vuelva a instalar la tapa del calentador y afiáncela con los cuatro tornillos que se proporcionan Deslice el calentador al in...

Page 9: ...tas garantías no son pertinentes para 1 Daños que sufra el producto por instalación o voltaje de suministro incorrectos 2 Daños que sufra el producto por mantenimiento incorrecto uso indebi do abuso accidente o alteraciones 3 Servicio que se le haya dado al producto por parte de personas o entidades ajenas a Cadet 4 Casos en que no se pueda determinar la fecha de fabricación del producto 5 Casos e...

Page 10: ...e de suministro incorrecto 3 El elemento ha fallado 1 Espere unos momentos para que el elemento alcance la temperatura de funcionamiento 2 Compruebe que el voltaje de suministro coincida con la calificación del calentador 3 Reemplace el elemento El calentador no se apaga 1 La fuga de calor de la habitación es superior a la capacidad del calentador 2 Termostato defectuoso 3 Termostato cableado al c...