MULTIPLE BASEBOARDS WITH ONE THERMOSTAT

Multiple baseboards can be wired in parallel on the same circuit (check national and local 

codes for safety requirements). Additional electrical supply wire and cable clamp connectors 

are required. The heaters must be in the same room.
The maximum amperage load you can put on one circuit breaker is limited to either 80% of 

the circuit breaker capacity, or the maximum amperage rating of the thermostat, 

whichever 

is lower

.

A

. Connect one supply wire to the 

red thermostat wire. 

B

. Connect the black thermostat 

wire to one wire from each heater. 

C

. Connect the remaining wire 

from each heater to the remaining 

supply wire. 

D

. Make a 3-wire connection with 

the two supply ground wires and 

the ground screw in heater #1.  

For 240 or 208 volt, both black and 

white supply wires are hot. Wrap 

supply (white) wires with black 

tape to identify them as hot!  

See Baseboard Owner’s Guide for 

baseboard #2 connections.

A

. Connect each of the two supply 

wires coming directly from the 

power supply, to each of the red 

thermostat wires. 

B

. Connect one black thermostat 

wire to one wire from each heater. 

C

. Connect the remaining black 

thermostat wire to the remaining 

wire from each heater. 

D

. Make a 3-wire connection with 

the two supply ground wires and 

the ground screw in heater #1.  

For 240 or 208 volt, both black and 

white supply wires are hot. Wrap 

supply (white) wires with black 

tape to identify them as hot!  

See Baseboard Owner’s Guide for 

baseboard #2 connections.

Cut one factory connection on each baseboard on the side you will be wiring. Two sets of 

electrical supply wire go through two cable clamp connectors of baseboard #1. One set of 

wires goes to the power supply and the other set goes to baseboard #2.

 There are two supply ground wires. You’ll need another short piece of copper wire to make 

the 3-wire connection with the ground screw in baseboard #1.

Tuck all the wires back into the individual wiring compartments, and make sure the connec

-

tions are tight. Attach with small screw at bottom.  
Proceed to OPERATING INSTRUCTIONS. 

 

BTF1

BTF2

A

B

C

A

baseboard #1

baseboard #2

wires to 

power supply

baseboard #1

baseboard #2

wires to 

baseboard #2

DO NOT 

CUT!

A

B

C

D

D

DO NOT 

CUT!

wires to 

power supply

wires to 

baseboard #2

additional 

copper wire 

connected 

here to 

grounding 

screw

additional 

copper wire 

connected 

here to 

grounding 

screw