MINERVA

 

10 inch FIR point source loudspeaker

Safety precautions

YOU ART. WE SOUND.

Potential risk of personal injury

Never stand in the direct sound beam close to a loudspeakers driven at a high level. 

Professional loudspeaker systems can cause sound pressure levels that could harm 

human health. Noncritical sound levels at about 90 dB can cause hearing damage if 

people are exposed to it over a longer period.

In order to prevent accidents when deploying loudspeakers on the ground or when 

flown, please take note of the following:

•  When setting up the loudspeakers or loudspeaker stands, make sure they are 

standing on a firm surface. If you place several systems on top of one another, use 

straps to secure them against movement.

•  Only use accessories which have been tested and approved by Cadenbach Acous-

tics for assembly and mobile applications. Pay attention to the correct application 

and maximum load capacity of the accessories.

•  Ensure that all additional hardware, fixings and fasteners used for installation or 

mobile use are of an appropriate size and load safety factor. Pay attention to the 

manufacturers instructions and to the relevant safety guidelines.

•  Regularly check the loudspeaker housings and accessories for visible signs of 

wear and tear, and replace them when necessary.

•  Regularly check all load bearing bolts in the mounting devices.

Potential risk of material damage

Loudspeakers produce a static magnetic field even if they are not connected or not 

in use. Therefore make sure when erecting and transporting loudspeakers that they 

are not near equipment and objects which may be impaired or damaged by an ex-

ternal magnetic field.

WARNINGS ON THE SPEAKERS BACK PLATE:

THIS EQUIPMENT CAN GENERATE EXTREME SOUND PRESSURE LEVELS THAT CAN LEAD TO 

PERMANENT HEARING DAMAGE.

THIS SURFACE MAY REACH HIGH TEMPERATURES WHILE IN USE.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO 

RAIN OR MOISTURE.

NO USER SERVICEABLE PARTS INSIDE.  REFER SERVICING TO QUALIFIED PERSONNEL.

ONLY PERSONAL CERTIFIED TO BE TRAINED BY CADENBACH ACOUSTICS, HAVING PASSED 

S1 COURSE SHOULD SETUP THIS SYSTEM, OTHERWISE ANY WARRANTY IS VOID. SEE COR-

RESPONDING MANUAL.

MADE IN GERMANY / EU

www.cadenbach.eu

Summary of Contents for MINERVA

Page 1: ...MINERVA Manual volume E 0 0 ...

Page 2: ...llation or mobile use are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visible signs of wear and tear and replace them when necessary Regularly check all load bearing bolts in the mounting devices Potential risk of material damage Loudspeakers produce ...

Page 3: ...t a 1 75 inch voice coil delivering extra high excursion possibilities and radiates distortion free sound also above 16 kHz TEUTATES is the dedicated low frequency extension anyway all cadenbach acoustic sub woofers can be chosen to run with MINERVA On order MINERVA incorporates a very power full frequency modulated floating modulator amplifier Due to it s advanced high efficiency power technology...

Page 4: ... Passive 1200 watts peak 600 watts AES 900 watts program rec amp power on 4 ohms 2800 watts Data Crossover type and frequency Filter type active FIR zero phase Low to Mid High 1 1 1 6 kHz Filter type passive NONE IIR FIR zero phase Low to Mid High 1 5 kHz Sub to Low 70 Hz 130 Hz Frequency and Phase response Usable frequency range 58 Hz 22 kHz 1 Free field frequency response 78 Hz 19 5 kHz 5 dB lin...

Page 5: ...E DIM 0 005 DIM 100 THD 0 02 N 20 Hz 20 kHz Audio input Connection XLR 5 pin iMINERVA XLR 3 pin female in and male link out 5pin 1g 2 LF 3 LF 4 HF 5 HF 3pin 1g 2 3 Audio input Impedance 20 kOhms symmetric between and 10 kOhms non symmetric grounded Ac Power connection Powercon 25 A blue in and white link max 12 6 A link Ac Power specifications 180 265 V AC 50 Hz 2200 VA iMinerva 110 V AC 60 Hz 300...

Page 6: ...Data Measurements Frequency response with FIR Filter of MINERVA Phase response FIR linear phase Filter of MINERVA www cadenbach eu MINERVA 10 inch FIR point source loudspeaker ...

Page 7: ...4 0 oo 24 6 8 10 12 14 18 24 POWER ON cadenbach acoustics P16die series system amplifier READY PROTECT SIGNAL BRIDGE BRIDGE CLIP NLR CH 2 dB CH 1 dB TEMP LIMIT TCL SUPPLY OVL 0 oo 24 6 8 10 12 14 18 24 0 oo 24 6 8 10 12 14 18 24 POWER ON cadenbach acoustics P16die series system amplifier READY PROTECT SIGNAL BRIDGE BRIDGE CLIP NLR CH 2 dB CH 1 dB TEMP LIMIT TCL SUPPLY OVL 0 oo 24 6 8 10 12 14 18 2...

Page 8: ...ase the signal must be reduced as soon as it sounds unnaturally distorted Damage caused by overloading the speakers or using the speakers with out Cadenbach Acoustics PAX and HEIMDALL we do not assume warranty and excludes liability for possible consequential damage Permanent high level signals with high frequency and continuous noise from feedback or permanently distorted high level signals or no...

Page 9: ...ave not been subject to any later design or electro mechanical modifications We herewith declare that said products are in conformity with the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from Cadenbach Acoustics WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separ...

Reviews: