SAFETY SYSTEM
12.1
INTRODUCTION
Safety devices are used to prevent and avoid the risk of damages to people, animales and objects.
It is forbidden to execute repearing by no authorized personnel otherwise the warranty and the manufacturer
liability fall.
Before of every intervention leave the fire completely extinguish till the cooling and always
disconnect the plug from the electric socket.
12.2
”BLACK OUT” ALARM
“ACTIVE ALARM” “AL 1 - BLACK OUT”: current breaking during ignition.
•
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and then is in “OFF”:
•
Clean the burning pot and start the stove up again with P4 key.
12.3
”EXHAUST PROBE” ALARM
To the exhaust is connected a probe which contantly controls the temperature during working time.
“ACTIVE ALARM” “AL 2 - EXHAUST PROBE”: the probe is damaged or disconnected.
•
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
•
Check the type of glitch as
.
•
Clean the burning pot and start the stove up again with P4 key.
12.4
”HOT EXHAUST” ALARM
If the fume probe registers a temperature at the exhaust higher then 180°C, the display shows “HOT EXHAUST”.
Then the combustible (pellet) drop will be decreased at phase 1.
This function has the aim to bring the values within preset values. If for any reason the temperature would not
decreas but increase, at 215°C the display shows “ACTIVE ALARM” “AL 3 - HOT EXHAUST” and the stove start the
switching off phase up.
•
Reset the error with P4 key. The stove carries out the phase “FINAL CLEANING” and the is in “OFF”.
•
Check the type of glitch as
.
•
Clean the burning pot and start the stove up again with P4 key.