19
SFERA3 - PRINCE3 - GLOBE AT - SFERA3 PLUS - SIRE3 PLUS - DOGE3 PLUS - PRINCE3 PLUS - ELISE3 PLUS - VEGA AT - TREND AT - VENUS3 PLUS - JOY AT
Fig. 22 - Door open
Fig. 23 - deteriorated gasket
Fig. 24 - Timer: 90 seconds
To operate correctly, the stove must work with the pellet hopper door always closed; should it remain open for
more than 90 seconds, the stove switches off.
• The loading system stops when the tank door is opened.
Before closing the lid, make sure there are no pellets below the gasket. Pellets deteriorate the gasket and
eliminate its airtight sealing. (vedi
10.4 VENTILATION
• The stove is endowed with a ventilation system.
• The air blown from fans keeps the appliance at a low temperature range in order to avoid high stresses to the materials which
make it up.
• Do not cover the hot air outlet slits with any object to avoid stove’s overheating!
• The stove is not suitable for food cooking.
Fig. 25 - Do not cover air slits
10.5 REMOTE CONTROL
• The stove can be operated through a remote control (optional)
• Operation requires 1 CR 2025 3 Volt Lithium battery
• Operating temperature 0 ° C / 50 ° C
• 38 khz infrared signal