RIVER IDROTECH 18 - 24 - 24H2O
18
7.3
CONNECTION DIAGRAM RIVER - IDROTECH 24 H
2
O DHW
Fig. 35 - Connection diagram DHW
LEGEND
A1
3/4”M heating water delivery
A2
3/4”M heating water return
A3
System filling / sanitary water inlet
A4
System draining
A5
Domestic hot water outlet
7.4
3 BAR DISCHARGE VALVE
There is a safety valve that can be inspected on the back of the stove under the pump. IT IS MANDATORY to connect a rubber hose
that is resistant to temperatures up to 110°C (not supplied) to the safety exhaust and run it to the outside in case water is dischar-
ged.
The manufacturer of the appliance is not liable for any flooding caused by the safety valves tripping if they
are not properly coupled to the outside of the product or to an appropriate collection and extraction system.
Fig. 36 - Discharge valve
LEGEND
A
3 bar CE PN10, TMAX 110°C safety valve
B
ATTENTION: 110°C !!