IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 - TESIS 16-23 AIRTIGHT - HIDROFIRE 22.8
11
min.3,5 metr
i
AT
(A)
AP
(B)
Fig. 3 - Flue
3.7
TECHNICAL FEATURES
Have a qualified technician check flue efficiency.
The flue must be airtight, vertical without constrictions, made with materials that are resistant to smoke and condensate, thermal-
ly insulated, and suited to resist normal mechanical stresses over time (we recommend circular section insulated twin wall chim-
neys in A/316 or refractory material). It must be externally insulated to prevent condensation and to reduce the smoke cooling
effect. It must not be near combustible or highly flammable materials with an air or insulating material gap: check the chimney
distance indicated by the manufacturer according to EN 1443. The chimney opening must be in the same room in which the ap-
pliance is installed or, at most, in an adjacent room and must have under the opening a soot and condensate collection chamber
that can be accessed via an airtight metal door.
A
B
C
D
E
Fig. 4 - Flat roof
LEGEND
A
0.50 metres
B
distance > 2 metres
C
distance < 2 metres
D
0.50 metres
E
technical volume