NX216-E ZONE EXPANDER

 

4

DEFAULT ZONE CONFIGURATIONS 

Zones can be programmed to be one of thirty different zone configurations (zone types). Configurations # 17 
through 20 can be used for wireless or hardwired zones using European double EOL configuration.  The default 
zone configurations are listed below.  These zone configurations can be customized by programming locations 
110 to 169.  NOTE #1: Zone Types 21-30 are applicable to the NX8-E control panel ONLY.    NOTE #2: The 
expander zones will not follow the Fast Loop Response. 
 

DATA

 

DESCRIPTION OF DEFAULT CONFIGURATION

 

“1” 

DAY ZONE - Instant when system is armed trouble zone when system is disarmed. 

“2” 

24-HOUR AUDIBLE  - Creates an instant yelping siren alarm regardless of the armed state of the panel. 

“3” 

ENTRY/EXIT DELAY 1 - A trip will start entry delay 1.  The lack of a trip during exit delay will enable the 
Automatic Bypass or Instant mode if so programmed. 

“4” 

FOLLOWER WITH AUTO-BYPASS DISABLED - This zone will be instant when the system is armed and 
no entry or exit delays are being timed. It is delayed during entry and exit delay times. This zone will not 
bypass in Stay Mode, nor automatically bypass even if enabled in Segment 1 / Location 23. 

“5” 

INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED - This zone will be instant when the system is 
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone 
will bypass in Stay Mode, and automatically bypass if enabled in Segment 1 of Location 23. 

“6” 

INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. 

“7” 

24-HOUR SILENT - Creates an instant silent alarm regardless of the armed state of the control panel. It will 
not display on the keypad. 

“8” 

FIRE - This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It 
will also rapidly flash the Fire LED indicating a trouble if the zone is open. 

“9” 

ENTRY/EXIT DELAY 2 - A trip will start entry delay 2.  The lack of a trip during exit delay will enable the 
Automatic Bypass or Instant mode if so programmed. 

“10” 

24-HOUR SILENT SUPERVISED - Creates an instant silent alarm regardless of the armed state of the 
control panel. It will display on the keypad. 

“11” 

KEYSWITCH ZONE - This zone type will arm and disarm the partition or partitions of the control panel that 
resides in each time the zone is shorted. Keyswitch arming will report as user #99. 

“12” 

INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED - This zone will be Instant when the system is 
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross 
Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an 
Instant alarm. This zone will bypass in Stay Mode and automatically bypass when enabled in Segment 1 of 
Location 23. 

“13” 

INSTANT ENTRY GUARD - This zone creates an instant alarm whenever it is tripped and the Stay LED is 
off.  It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on. 

“14” 

ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1.  This zone will 
bypass when the "Group Bypass" command is entered at the keypad.   The lack of a trip during exit delay 
will enable the Automatic Bypass or Instant mode if so programmed. 

"15 

INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is 
armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will 
bypass when the "Group Bypass" command is entered at the keypad. This zone will bypass in Stay Mode 
and automatically bypass even if enabled in Segment 1 / Location 23. 

"16" 

INSTANT WITH GROUP BYPASS ENABLED  - This zone creates an instant alarm whenever it is tripped 
and the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at the 
keypad. 

"17" 

ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED - A trip will start entry delay 1.  The lack of a trip during 
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group 
can be used to enable tamper on a wireless transmitter. 

"18" 

INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED - This zone will be instant when 
the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit delay 
times. This zone will bypass in Stay Mode and automatically bypass if enabled in Segment 1 / Location 23. 
This configuration group can be used to enable tamper on a wireless transmitter. 

"19" 

INSTANT WITH TAMPER ENABLED - This zone creates an instant alarm whenever it is tripped and the 
Armed LED is on. This configuration group can be used to enable tamper on a wireless transmitter. 

"20" 

ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED - A trip will start entry delay 2.  The lack of a trip during 
exit delay will enable the Automatic Bypass or Instant mode if so programmed. This configuration group 
can be used to enable tamper on a wireless transmitter.

 

Summary of Contents for NX216-E

Page 1: ...ntents Page General Description 2 6 Position Dip Switch Settings 2 Enrolling the NX216 E Expander 2 Wiring the NX216 E 3 Terminal Description 3 Wiring Diagram 3 Default Zone Configurations 4 Programmi...

Page 2: ...FF OFF 57 21 ON ON ON OFF OFF 65 96 OFF OFF OFF ON OFF 73 97 ON OFF OFF ON OFF 81 98 OFF ON OFF ON OFF 89 99 ON ON OFF ON OFF 97 100 OFF OFF ON ON OFF 105 101 ON OFF ON ON OFF 113 102 OFF ON ON ON OFF...

Page 3: ...Connect as shown below IF NOT USED CONNECT TO A COM TERMINAL AUX Can be used to power devices directly from the NX216 E Power is coming from the NX8 NX8 E therefore the current draw of these devices...

Page 4: ...eport as user 99 12 INTERIOR FOLLOWER WITH CROSS ZONE ENABLED This zone will be Instant when the system is armed and no entry or exit delay is being timed It is delayed during entry and exit delay tim...

Page 5: ...ABLED This zone will be instant when the system is armed and no entry or exit delay is being timed It is delayed during entry and exit delay times It will send a report if the zone activity time is re...

Page 6: ...ONES 17 24 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 30 ZONES 17 24 PARTITION SELECT Segment 1 2 3 4 5 6 7 8 Zone 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Page 7: ...8 Zone 49 50 51 52 53 54 55 56 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 172 ZONES 57 64 CONFIGURATION GROUP 6 6 6...

Page 8: ...4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 180 ZONES 89 96 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 181 ZONES 89 96 PARTITION...

Page 9: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 188 ZONES 121 128 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 189 ZONES 121 128 P...

Page 10: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 196 ZONES 153 160 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 197 ZONES 153 160 P...

Page 11: ...84 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 203 ZONES 177 184 PARTITION SELECT Segment 1 2 3 4 5 6 7 8 Zone 177 178 179 180 181 182 183 184 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1...

Page 12: ...AW 30mA LOOP RESISTANCE 300 Ohms Maximum LOOP RESPONSE Selectable 50mS or 500mS OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 6 0 Wide 2 125 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS I...

Reviews: