![background image](http://html1.mh-extra.com/html/cadac/mighty-4/mighty-4_user-instructions_3246590004.webp)
2
2
3. Assembly Instructions
PLEASE NOTE:
Please ensure all protective packaging and plastic are removed from the appliance before use.
This appliance may only be used with an approved hose and regulator.
The hose length should be no less than 600 mm and shall not exceed 1.2 m and replace when the hose is damaged or shows signs of brittleness
or cracks.
Do not twist or pinch the hose. Ensure that it is routed away from the stove body so as to prevent deterioration / damage to the hose
caused by heat.
Ensure that the appliance valves are in the off position by turning the knobs fully clockwise to the stop.
Open the gas valve on the cylinder and test for any leaks.
Check all gas connections for any signs of gas leaks.
Your appliance is now ready to be used.
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37),
Appliance categories: (DK, FI, NO, NL, SE, AT, DE, BE, ES, FR, IE, IT, PT, GB, CH)
Push an approved hose onto the valve tailpiece until it is properly seated. On the other end, attach a suitable low pressure regulator.
I3B/P(30) : 30mbar Butane configurations regulator or 30mbar Propane configurations regulator.
I3B/P(37) : 37mbar Butane configurations regulator or 37mbar Propane configurations regulator.
I3+(28-30/37) : 30mbar Butane configurations regulator or 37mbar Propane configurations regulator.
Again making sure that the hose is properly seated. The type of hose used shall comply with the relevant EN standard and locate
requirement. In South Africa the regulator used must comply with SANS 1237.
I 3B/P (50) Appliance category: (AT, DE)
I3B/P(50) : 50mbar Butane configurations regulator or 50mbar Propane configurations regulator or 50mbar butane/propane mixture
configurations regulator.
Screw a hose with the correct threaded fittings on each end, onto the left hand 1/4” BSP thread of the valve. Attache a suitable 50mbar
low-pressure regulator on the end of the hose. The hose assembly used must comply with DIN 4815 part 2 or equivalent.
Country Name and Abbreviations
AE = United Arab Emirates
AL = Albania
AT = Austria
BE = Belgium
CH = Switzerland
CZ = Czech Republic
DE = Germany
DK = Denmark
ES = Spain
FI = Finland
FR = France
GB = United Kingdom
GR = Greece
HR = Croatia
IT = Italy
JP = Japan
KR = Korea
NL = Netherlands
NO = Norway
PL = Poland
PT = Portugal
RO = Romania
RU = Russia
RS = Serbia
SI = Slovenia
SK = Slovakia
SE = Sweden
TR = Turkey
ZA = South Africa
GB
Model: 400
Country of Use
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, LU, LV,
PT, SK & SI
PL
BE, CY, DK, EE, FR, FI,
HU, IT, LT, NL, NO, SE,
SI, SK, RO, HR, TR, BG,
IS,LU, MT
,
& ZA
AT, CH, DE & SK
Appliance Catagories
I
3+(28-30/37)
I
3B/P (37)
I
3B/P (30)
I
3B/P (50)
Allowable gasses
Butane
Propane
Butane, Propane or their mixture
Gas Pressure
28-30mbar
37mbar
37mbar
28-30mbar
50mbar
Ø110 burner jet no.
86
86
86
75
Ø110 burner nominal
usuage
Butane - 240g/h per
burner
(240g/h x 2 = 480g/h
in total)
Butane - 268g/h per
burner
(268g/h x 2 = 536g/h
in total)
Butane - 240g/h per
burner
(240g/h x 2 = 480g/h
in total)
Butane - 240g/h per
burner
(240g/h x 2 =
480g/h in total)
Ø110 burner gross
nominal heat input
3.3kW per burner
(3.3kW x 2 = 6.6kW in
total)
3.6kW per burner
(3.6kW x 2 = 7.2kW
in total)
3.3kW per burner
(3.3kW x 2 = 6.6kW
in total)
3.3kW per burner
(3.3kW x 2 = 6.6kW
in total)
Ø75 burner jet no.
72
72
72
63
Ø75 burner nominal
usuage
Butane - 168g/h per
burner
(168g/h x 2 = 336g/h
in total)
Butane - 187g/h per
burner
(187g/h x 2 = 374g/h
in total)
Butane - 168g/h per
burner
(168g/h x 2 = 336g/h
in total)
Butane - 168g/h per
burner
(168g/h x 2 =
336g/h in total)
Ø75 burner gross nomi-
nal heat input
2.3kW per burner
(2.3kW x 2 = 4.6kW in
total)
2.6kW per burner
(2.6kW x 2 = 5.2kW
in total)
2.3kW per burner
(2.3kW x 2 = 4.6kW
in total)
2.3kW per burner
(2.3kW x 2 = 4.6kW
in total)