background image

2

2

3. Assembly Instructions 

PLEASE NOTE: 

Please ensure all protective packaging and plastic are 

removed from the appliance before use.

This appliance may only be used with an approved hose and 

regulator.

Connect the regulator to a CADAC 3kg, 5kg or 7kg LPG cylinder prior 

to use (Fig. 1).

If you wish to use the appliance with a 9kg cylinder, please ensure 

that you have purchased the correct hose and regulator suitable for a 

9kg cylinder (Fig. 2).

The hose length should be no less than 600 mm and shall not 

exceed 1.2 m and replace when the hose is damaged or shows signs 

of brittleness or cracks.

Do not twist or pinch the hose. Ensure that it is routed away from 

the Stove Body so as to prevent deterioration / damage to the hose 

caused by heat.

Ensure that the appliance valves are in the off position by turning the 

knobs fully clockwise to the stop.

Open the gas valve on the cylinder and test for any leaks.

Check all gas connections for any signs of gas leaks.

Your appliance is now ready to be used.

Model: 400

Appliance catagories

I

3B/P (30)

Allowable gasses

Butane, Propane or their mixture

Gas pressure

2.8kPa

Ø110 burner jet no.

86

Ø110 burner nominal usuage

Butane - 240g/h per burner

(240g/h x 2 = 480g/h in total)

Ø110 burner gross nominal heat input

3.3kW per burner

(3.3kW x 2 = 6.6kW in total)

Ø75 burner jet no.

72

Ø75 burner nominal usuage

Butane - 168g/h per burner

(168g/h x 2 = 336g/h in total)

Ø75 burner gross nominal heat input

2.3kW per burner

(2.3kW x 2 = 4.6kW in total)

GB

4. Fitting and Changing the Gas Cylinder

•  Before connecting the appliance to a gas cylinder, ensure that the rubber seal on the 

Regulator is in position and in good condition.

•  Carry out this check each time you fit the appliance to a gas cylinder.
•  Blow out any dust from the cylinder opening to prevent possible blockage of the jet.
•  Ensure that the appliance valves are in the off position by turning the knobs fully clockwise 

to their stop.

•  Ensure that the gas cylinder is fitted or changed in a well-ventilated location, preferably 

outdoors, away from any source of ignition, such as naked flames and away from other 
people.

•  Make sure that the gas cylinder is kept upright at all times, connect to the cylinder by 

screwing on hand tight until fully engaged. 

•  Ensure that a complete gas seal has been made (check for the smell of gas around the 

connection joint). If there is a leak on your appliance (smell of gas), take it outside 
immediately into a well-ventilated flame free location where the leak may be detected and 
stopped. To check for leaks on your appliance, do it outside using warm soapy water only, 
which is applied to the joints and connections of the appliance. A formation of bubbles will 
indicate the gas leak. Do not check for leaks with a naked flame.

•  If you cannot rectify the gas leak do not use the appliance, contact your local CADAC 

stockist for assistance. 

•  CADAC gas cylinder valves must only be repaired by an authorised CADAC service centre or 

dealer.

•  When changing a gas cylinder firstly close the appliance control knobs and then the cylinder valve, making sure the flame is  

extinguished, unscrew the regulator. Re-fit the regulator to a full cylinder following the same precautions as described above.

Fig. 4

Fig. 5

503-0674 LEV6 (400, 400F) Mighty 4 Stove - User Manual (SA).indd   2

2021/02/23   08:34:24

Summary of Contents for 400F

Page 1: ...0674 LEV6 MODEL No 400 400F 2 8kPa USER INSTRUCTIONS LIVE THE BRAAI LIFE NOTE PRODUCT MAY VARY FROM ILLUSTRATIONS GB 1002 148 2 RSA 17 A 503 0674 LEV6 400 400F Mighty 4 Stove User Manual SA indd 1 20...

Page 2: ...503 0674 LEV6 400 400F Mighty 4 Stove User Manual SA indd 2 2021 02 23 08 34 13...

Page 3: ...Minimum safe distances above the appliance 1 2 m at the rear and sides 600mm Fig 3 Do not use an appliance that is leaking damaged or which does not operate properly Ensure that the gas cylinder is f...

Page 4: ...e to a gas cylinder ensure that the rubber seal on the Regulator is in position and in good condition Carry out this check each time you fit the appliance to a gas cylinder Blow out any dust from the...

Page 5: ...lve after connecting to and opening the cylinder valve by turning the control knob E in an anti clockwise direction Light the appliance burners Use the control knob to adjust the flame intensity to th...

Page 6: ...ashed in a detergent solution To clean the stove body simply wipe with a damp cloth using a little detergent if necessary DO NOT IMMERSE IN WATER as this will allow water to get into the burner tube c...

Page 7: ...Do not modify the appliance Any modification of the appliance may be dangerous Any modifications will render the CADAC warranty null and void If you cannot rectify any fault by following these instru...

Page 8: ...ailure to perform normal and routine maintenance including but not limited to damage caused by insects within the burner tubes as set out in this owner s manual Deterioration or damage due to severe w...

Page 9: ...7 7 503 0674 LEV6 400 400F Mighty 4 Stove User Manual SA indd 7 2021 02 23 08 34 35...

Page 10: ...arin Co Unit D 6th Floor Negin Zafar Building No 1327 Shariati Street Tehran Iran Tel 98 21 276 00 781 Mail info cadac ir CADAC MOZAMBIQUE Exclusive Brands Africa 492 Avenida Namaacha Maputo Mozambiqu...