100 Series Industrial Grade UFD Product Manual v2.0
Cactus Technologies
®
8
The following table defines all D.C. Characteristics for the UFD. Unless otherwise stated, conditions
are:
Vcc = 5V ± 10%
Ta = 0°C to 70°C
The following sections provide detailed information on the Cactus Technologies® Industrial UFD
interface.
Electrical Specification
3.1.
Interface
Description
03
Parameter
Symbol
MIN
MAX
Units
Storage Temperature
Ts
-55
150
oC
Operating Temperature
T
A-
-45
90
oC
Vcc with respect to GND
Vcc
-0.3
6.5
V
3.1.1. Absolute Maximum Ratings
Parameter
Symbol
MIN
MAX
Units
Input Levels USB D+,D-, Full
Speed Mode
Low
High
V
iL
V
IH
-
2.0
0.8
-
V
Output Levels USB D+, D-, Full
Speed Mode
Low
High
V
OL
V
OH
0
2.8
0.3
3.6
V
Output Signal Crossover
Voltage USB D+, D-, Full Speed
Mode
V
CRS
1.3
2
V
Input Levels USB D+, High
Speed Mode
Low
High
V
IL
V
IH
-10
360
10
440
mV
Input Levels USB D-, High
Speed Mode
Low
High
V
IL
V
IH
360
-10
440
10
mV
3.1.2. DC Characteristics