5
Internal Jumper Options
Isolation Jumpers- This jumper provides three different ground isolation
options for the input of the coe8. The three input options include GND,
Isolation, and 200ohms. Make sure the coe6 is turned off before making
your selection.
Blending Jumpers- These jumpers are used to select either a Direct
(separate) or a Blended (summed) output. In the direct position the signal
on an individual channels input will come out the same channels output. In
the blended position the signals on two or more channels can be combined
with Channel 1 to provide one full range output. All of the channels that have
been selected to have their inputs blended will be combined and output onto
Channel 1. Each of the remaining channels being blended (2, 3, & 4) will
have the same signal on their channels output as what is on their input (not
a full range output like Channel 1).
A
B
* coe8 shown with top cover removed.
200Ω
GND
ISO
Direct
Blend
Blend
Blend
Direct
Direct
B
A