REMOTE CONTROL

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage.

Handle the control with care and avoid getting the control wet.

CAUTION

!

NOTE: The remote control is factory set to display
temperatures in

_

F. If

_

C is desired, turn the remote off and

then press the “MODE” and “--” buttons on the remote
simultaneously.
IMPORTANT

: The remote control can operate the unit from a

distance of up to 25 ft. (7.6 m) as long as there are no obstructions.
This is one way communication only (from remote control to fan
coil).
The remote control can perform the following basic functions:

S

Turn the system ON and OFF

S

Select operating mode

S

Adjust room air temperature set point and fan speed

S

Adjust airflow direction

Refer to the

Remote Control Function

section for detailed

description of all the capabilities of the remote control.

Battery Installation

Two AAA 1.5 v alkaline batteries (included) are required for

operation of the remote control.
To install or replace batteries :

1. Slide the back cover off the control to open the battery com-

partment.

2. Remove old batteries if you are replacing the batteries.
3. Insert batteries. Follow the polarity markings inside the

battery compartment.

4. Replace battery compartment cover.

A08299

NOTE:

1. When replacing batteries, do not use old batteries or a different

type battery. This may cause the remote control to malfunction.

2. If the remote is not going to be used for several weeks, remove

the batteries. Otherwise battery leakage may damage the remote

control.

3. The average battery life under normal use is about 6 months.

4. Replace the batteries when there is no audible beep from the

indoor unit or if the Transmission Indicator fails to light.

Setting the Clock

Before you start operating the air conditioner, set the clock on the

remote control as outlined below. The clock panel on the remote

controller will display the time regardless of whether the air

conditioner is in use or not.
Initial Setting of the Clock:
After batteries are inserted in the remote control, the clock panel

will display ”12:00”.

1. Push the CLOCK button once

will flash.

2. Push the “+” or “--” button. Each time you press the button,

the time moves forward or backward by one minute de-

pending on which button you press.

If you push the “+” or “--” button continuously, the time

adjusts in increments of 10 minutes.

3. When the right time is achieved, press the CLOCK button

once to set the time. The

will stop flashing.

4. To readjust the Clock, Press the CLOCK button on the

remote. The

will flash. Repeat steps 1 through 3.

NOTE: The time of the CLOCK must be set before the
AUTO--TIMER function will operate.

UNIT OPERATION HAZARD

Failure to follow this caution may result in equipment damage or

improper operation.

Static electricity or other factors (voltage fluctuations) can cause

the remote control clock to reset. If your remote control is reset

(the time of ”12:00” flashing), set the clock before starting the

unit.

CAUTION

!

Remote Control Operation -- Quick Start

NOTE:

When transmitting a command from the remote control to

the unit, be sure to point the control toward the LED display on the
front panel of the unit. The unit will confirm receipt of a command
by sounding an audible beep.

1. Turn the unit on by pushing the

ON/OFF

button.

2. Select the desired mode by pushing the mode button.

(Only for heating and cooling units)

A08301

NOTE:

Cool Only units have no heat mode.

3. Select the temperature set point by pointing the control to-

ward the unit and pressing the “+” or “--” temperature set

point buttons until the desired temperature appears on

screen. In AUTO mode, the setpoint temperature is not ad-

justable.

4. Select the desired fan speed by pressing the

FAN

button to

select desired fan speed.

NOTE:

If unit is operating in Dry mode (X--FAN), low fan speed

will be displayed and the fan speed cannot be changed.

5. Set the airflow direction. When the unit is turned on, the

louvers default to the cooling or heating position. The user
can adjust the default louver position by pushing the
“SWING” buttons. For details on operating the SWING

louvers, refer to the Remote Control Functions section.

Emergency Operation

If the remote control is lost, damaged, or the batteries are

exhausted, the

AUTO

button on the unit can be used to

temporarily operate the unit.
Open the front cover panel and press the AUTO button once

briefly when the system is off.
To stop emergency operation, push the

AUTO

button once. The

emergency operation can also be stopped by pushing the

“ON/OFF” button on the remote control.

Summary of Contents for 40GVM

Page 1: ...convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful sho...

Page 2: ...wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the r...

Page 3: ...ontrol holder 7 1 2 3 5 6 8 9 10 4 7 Front Panel Frame Display Panel shown for 40GXM units Front Panel Air Filter Horizontal Airflow Louver Manual Adjustable Vertical Airflow Louver Remote Control Roo...

Page 4: ...and Down Buttons 5 Fan Speed 6 Horizontal Louver Swing Button 7 Clock Button 8 Timer ON Button 9 Dry Coil Button 10 Temperature Button 11 Timer OFF Button 12 Turbo Mode Button 13 Sleep Mode button 14...

Page 5: ...ing in AUTO mode 4 MODE DISPLAY Indicates the current operation mode AUTO COOL DRY FAN ONLY or HEAT 5 SLEEP DISPLAY Indicates unit is running in SLEEP mode 6 TEMPERATURE DISPLAY Temperature setting fr...

Page 6: ...ress the button the time moves forward or backward by one minute de pending on which button you press If you push the or button continuously the time adjusts in increments of 10 minutes 3 When the rig...

Page 7: ...nel will turn red and the remote control will display the setpoint and time OPER will disappear NOTE If the On Off button is pressed too soon after a stop the compressor will not start for 3 minutes d...

Page 8: ...ry modes to ensure that additional moisture is removed from coil Push the X FAN button to enable this feature This will be displayed on remote control OPER F C HOUR ON OFF Remote Dry Coil Icon A09637...

Page 9: ...ll continue operating normally NOTE When the unit is shut off by the user using the ON OFF button and if the TIMER ON is set the following will be displayed on the remote control Set Point Time Clock...

Page 10: ...ng Features If the unit is in the heating mode there will be a delay when the fan starts The fan will start only after the coil is warmed up to prevent cold blow Defrost Operation In heating mode if t...

Page 11: ...ay result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 56_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they m...

Page 12: ...call your representative Unit System Does Not Work To protect the unit upon an immediate restart after a stop the system controller will delay the unit for 3 minutes before allowing the unit to start...

Reviews: