characteristic of the amplifier.
When making adjustments always apply the following principles:
Input signal levels should ALWAYS exceed the noise figure of the amplifier by 3 to 6
dB.
The primary purpose of tilt (equalization) in a cable TV plant is to compensate for the
slope generated in coaxial cable between the high and low TV frequencies. When
various TV channels, with respect to frequency, are transmitted through coaxial cable
they are subjected to increasing attenuation (loss). Simply put, as the frequencies of
the TV carriers are increased, attenuation loss (dB) increases. A variable tilt control is
installed in this amplifier to compensate for this slope in cable resulting in a flat
frequency response at the output
6
. TROUBLESHOOTING
a. Ensure you are using quality multiple shielded cables with quality radial or
compression F-connectors.
b. Ensure the F-connector’s center conductor is making solid contact with the
CTA-35-1000PR’s Input and Output ports, and the appropriate RF source and RF
distribution network connectors.
c. When taking measurements it is always best to use an RF spectrum analyzer or
quality signal level meter. Initially, level measurements should be taken from the
CTA-35-1000PR’s Output port. However, for testing while the amplifier is in service
use the Input Test and Output Test ports for setup and field maintenance. Note that
each Test port is padded down –20 dB and the 20 dB must be added back in when
determining level settings and output.