background image

 

characteristic of the amplifier. 
 
When making adjustments always apply the following principles: 
 

 

Input signal levels should ALWAYS exceed the noise figure of the amplifier by 3 to 6 
dB.  

 

  

 

The primary purpose of tilt (equalization) in a cable TV plant is to compensate for the 
slope  generated  in  coaxial  cable  between  the  high  and  low  TV  frequencies.  When 
various TV channels, with respect to frequency, are transmitted through coaxial cable 
they are subjected to increasing attenuation (loss). Simply put, as the frequencies of 
the TV carriers are increased, attenuation loss (dB) increases. A variable tilt control is 
installed  in this  amplifier  to  compensate  for  this  slope  in  cable  resulting  in  a  flat 
frequency response at the output

 

 
 

6

.  TROUBLESHOOTING 

 

a.  Ensure  you  are  using  quality  multiple  shielded  cables  with  quality  radial  or 

compression F-connectors. 

 
b.  Ensure  the  F-connector’s  center  conductor  is  making  solid  contact  with  the 

CTA-35-1000PR’s  Input  and  Output  ports,  and  the  appropriate  RF  source  and  RF 
distribution network connectors. 

 

c.  When  taking  measurements  it  is  always  best  to  use  an  RF  spectrum  analyzer  or 

quality  signal  level  meter.      Initially,  level  measurements  should  be  taken  from  the 
CTA-35-1000PR’s Output port.  However, for testing while the amplifier is in service 
use the Input Test and Output Test ports for setup and field maintenance.  Note that 
each Test port is padded down –20 dB and the 20 dB must be added back in when 
determining level settings and output.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 