CableTronix CTA-30-870AR Installation Manual Download Page 5

 

When making adjustments always apply the following principles: 
 

 

Input signal levels should ALWAYS exceed the noise figure of the amplifier by 3 to 6 
dB.  

 

  

 

The primary purpose of tilt (equalization) in a cable TV plant is to compensate for the 
slope  generated  in  coaxial  cable  between  the  high  and  low  TV  frequencies.  When 
various TV channels, with respect to frequency, are transmitted through coaxial cable 
they are subjected to increasing attenuation (loss). Simply put, as the frequencies of 
the TV carriers are increased, attenuation loss (dB) increases. A variable tilt control is 
installed  in this  amplifier  to  compensate  for  this  slope  in  cable  resulting  in  a  flat 
frequency response at the output

 

 
 

6

.  TROUBLESHOOTING 

 

a.  Ensure  you  are  using  quality  multiple  shielded  cables  with  quality  radial  or 

compression F-connectors. 

 
b.  Ensure  the  F-connector’s  center  conductor  is  making  solid  contact  with  the 

CTA-30-870AR’s  Input  and  Output  ports,  and  the  appropriate  RF  source  and  RF 
distribution network connectors. 

 

c.  When  taking  measurements  it  is  always  best  to  use  an  RF  spectrum  analyzer  or 

quality  signal  level  meter.      Initially,  level  measurements  should  be  taken  from  the 
CTA-30-870AR’s Output port.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

This is a notice to inform you that content passing thru this device may contain strong 

language or depictions of violence, sex or substance abuse.  This unit contains no 

parental control features. Parental discretion is advised.

 

Summary of Contents for CTA-30-870AR

Page 1: ...1 INSTALLATION MANUAL CTA 30 870AR 2 Way Wall Mount Distribution Amplifier ...

Page 2: ...70AR Two Way Wall Mount Distribution Amplifier Specifications Typical RF Forward Path 1 Bandwidth 54 870 MHz forward path 2 Forward Gain 30 dB 3 Gain Adjust Range 0 10 dB variable 4 Flatness 1 dB maximum 54 870MHz 5 Tilt Control Range 10 dB 6 Noise Figure 6 dB 54 550MHz 4 dB 550 870 MHz 7 Return Loss 14 dB 54 550 MHz 12 dB 550 870 MHz 8 Input Level 45 dBmV 67 25 MHz 9 Impedance Input Output 75Ω Re...

Page 3: ...or shipping damage Make sure the equipment is clean and no connectors are broken damaged or loose If equipment appears to be damaged or defective please contact us at 1 610 429 1511 for assistance 3 PRODUCT DIAGRAM NOTE TO SYSTEM INSTALLER System installer must adhere to Article 820 40 of the NEC that provides guidelines for proper grounding and specifies that the cable ground shall be connected t...

Page 4: ...e load if the CTA 30 870AR and other equipment are being powered by it 5 ADJUSTMENT The chart below shows the proper operation levels for the CTA 30 870AR Note the listed performance criteria are for specific numbers of channels and must be de rated accordingly when inserting additional channels However the amplifier s gain does not change Therefore as the number of channels increases from seven 7...

Page 5: ...ompensate for this slope in cable resulting in a flat frequency response at the output 6 TROUBLESHOOTING a Ensure you are using quality multiple shielded cables with quality radial or compression F connectors b Ensure the F connector s center conductor is making solid contact with the CTA 30 870AR s Input and Output ports and the appropriate RF source and RF distribution network connectors c When ...

Reviews: