Chapter 1: Installation

1-2

SWPIM-E1 Installation Guide

1.2

INSTALLING THE SWPIM-E1 

The SWPIM-E1 can be installed in any available open slot in the host 
platform. To install the SWPIM-E1, proceed as follows:

1. Unfasten the screw and remove the blank panel covering the slot in the 

host platform in which the SWPIM-E1 will be installed. See 
Figure 1-1.

2. Ensure that the antistatic wrist strap is attached and used as 

recommended. 

3. Remove the SWPIM-E1 from the plastic bag. (Save the bag in the 

event the device must be removed from the host platform).

4. Hold the SWPIM-E1 with the faceplate facing away (right side up) 

from the host platform. The 40-pin connector should be facing towards 
the empty slot, with the wide part of the connector oriented down, as 
shown in Figure 1-1.

5. Locate the rail guides inside the slot in which the SWPIM-E1 will be 

installed. See Figure 1-1.

6. Install the SWPIM-E1 in the host platform by aligning the SWPIM-E1 

with the rail guides in the host platform and sliding it in. Take care that 
the SWPIM-E1 slides in straight and properly engages the backplane 
host connector. Do not force the device. 

NOTE

It is not necessary to power down the host platform to install 
the SWPIM-E1.

!

CAUTION

Observe all precautions to prevent damage from Electrostatic 
Discharge (ESD).

Summary of Contents for SWPIM-E1

Page 1: ...SWPIM E1 LNK STS Title Page SWPIM E1 Installation Guide 9033059 02 ...

Page 2: ......

Page 3: ... OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Cabletron Systems Inc 35 Industrial Way Rochester NH 03867 1999 by Cabletron Systems Inc All Rights Reserved Printed in the United States of America Order Number 9033059 02 October 1999 Cabletron Systems SPECTRUM and LANVIEW are registered trademarks and SmartSwitch is a trademark of Cabletron Systems Inc All other product names mentio...

Page 4: ...ly the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLICABLE LAW This Licen...

Page 5: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Page 6: ... the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the Program 3 APPLI...

Page 7: ... computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3 ...

Page 8: ...LICENSE You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron 2 OTHER RESTRICTIONS You may not reverse engineer decompile or disassemble the...

Page 9: ...d computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the Product is considered commercial computer software in accordance with DFARS section 227 7202 3...

Page 10: ... 55022 EN 50082 1 EN 60950 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above directives Manufacturer Legal Representative in Europe Mr Ronald Fotino Mr J Solari ___________________________________ __________________...

Page 11: ...NSTALLATION 1 1 Unpacking the SWPIM E1 1 1 1 2 Installing the SWPIM E1 1 2 1 3 LANVIEW LED Indications 1 4 1 4 Connecting to the Network 1 5 1 5 Completing the Installation 1 5 APPENDIX A SPECIFICATIONS A 1 Physical Properties A 1 A 2 Network Interface A 1 A 2 1 Pinouts for the E1 Interface Connector A 2 A 3 E1 Cable Assembly A 2 A 4 Environmental Requirements A 3 A 5 Regulatory Compliance A 3 ...

Page 12: ...Contents x SWPIM E1 Installation Guide ...

Page 13: ...3 data communications networks and their physical layer components is helpful before using the SWPIM E1 STRUCTURE OF THIS GUIDE This guide is organized as follows This Introduction provides preliminary information that will aid in using this manual lists technology and user s guides that may help the user to set up and manage the SWPIM E1 gives an overview of the SWPIM E1 and its features and info...

Page 14: ...onfigure the SWPIM E1 using software The SWPIM E1 uses a single RJ48 connector supporting the E1 interface Refer to Appendix A for the Cabletron Systems part number and pin assignments for the E1 interface cable Internal CSU DSU The SWPIM E1 provides an E1 interface that includes a built in Channel Service Unit Digital Service Unit CSU DSU for direct connection to an E1 line This SWPIM supports bo...

Page 15: ... indicate link and status conditions Refer to Chapter 1 for more details The SWPIM E1 also gathers statistics such as bipolar violations and frame errors that are available through the management software RELATED MANUALS The following Cabletron Systems manuals may help the user to set up and manage the SWPIM E1 SSR 600 Installation Guide HSIM SSR 600 Installation Guide 6C105 SmartSwitch 6000 Overv...

Page 16: ...nfigurator User s Guide Systems Network Architecture Guide Quick Reference Guide DTF Data Trace Facility User Guide DOCUMENT CONVENTIONS The following conventions may be seen in this document NOTE Note symbol Calls the reader s attention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains...

Page 17: ...tems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA numbers World Wide Web http www cabletron com Phone 603 332 9400 Internet mail support cabletron com FTP ftp ...

Page 18: ...Introduction xvi SWPIM E1 Installation Guide ...

Page 19: ...IM E1 2 Attach the antistatic strap refer to the instructions in the antistatic wrist strap package before removing the SWPIM E1 from the antistatic packaging 3 Verify that the SWPIM E1 is undamaged Refer to Getting Help if there is any damage to the device Do not attempt to install the SWPIM E1 if it is damaged Only qualified personnel should install the SWPIM E1 CAUTION Failure to observe static...

Page 20: ...tform 4 Hold the SWPIM E1 with the faceplate facing away right side up from the host platform The 40 pin connector should be facing towards the empty slot with the wide part of the connector oriented down as shown in Figure 1 1 5 Locate the rail guides inside the slot in which the SWPIM E1 will be installed See Figure 1 1 6 Install the SWPIM E1 in the host platform by aligning the SWPIM E1 with th...

Page 21: ...1 must be configured before the WAN connection is made Once the SWPIM E1 has been configured the host platform must undergo a soft or hard restart in order for the SWPIM E1 to be recognized and for traffic to pass Refer to the appropriate software manual to configure the SWPIM E1 CAUTION Do not connect any WAN cables until the software configuration for the SWPIM E1 has been done The phone company...

Page 22: ... Link LED Color Indication Off Disabled or Not Configured Red No Link Amber Transmit or Receive Traffic Green Port is Active Blinking Green Port is in Test Mode Table 1 2 Status LED Color Indication Off Normal or Disabled Red Receive Carrier Loss RCL Amber Receive Remote Alarm RRA Receive Signaling All Zeros RSA0 Blinking Amber Loopback Test Mode Blinking Green Receive Signaling All Ones RSA1 Rece...

Page 23: ...onfiguration for the SWPIM E1 Figure 1 2 SWPIM E1 Typical Configuration 1 5 COMPLETING THE INSTALLATION After installation the SWPIM E1 will need to be configured for the network Refer to the host platform software documentation to set up and manage the SWPIM E1 SSR 600 SWPIM E1 Site 1 SSR 600 SWPIM E1 Site 2 WAN Cloud ...

Page 24: ...Chapter 1 Installation 1 6 SWPIM E1 Installation Guide ...

Page 25: ...ons at any time without notice Pinouts and the E1 cable are also listed in this appendix A 1 PHYSICAL PROPERTIES A 2 NETWORK INTERFACE The connector for the RJ48 network port can be seen in Figure A 1 Figure A 1 RJ48 Pinout Dimensions 1 91 H x 5 40 W x 19 05 D cm 0 75 H x 2 125 W x 7 50 D in Weight Unit 068 kg 0 15 lb Nominal current draw on 5V supply from host platform 150 mA MTBF Predicted 10 11...

Page 26: ...r may specify the length of cable when ordering Table A 1 Pinouts for the E1 Interface Connection Pin Signal 1 Receive Ring 2 Receive Tip 3 Shield Ground 4 Transmit Ring 5 Transmit Tip 6 Shield Ground 7 Shield Ground 8 Shield Ground Table A 2 SWPIM E1 Cable Part Numbers Interface Cable Cabletron Part Number 20 foot E1 Line Interface Cable 9372095 201 1 Standard 20 foot E1 Line Interface Cable E1 L...

Page 27: ...372095 L Description E1 line interface cable Connector 1 RJ45 Connector 2 RJ45 Operating Temperature 5 to 40 C 41 to 104 F Non operating Temperature 30 to 90 C 22 to 194 F Operating Humidity 5 to 90 Non condensing Safety EN 60950 IEC 950 73 23 EEC EMI EN 55022 Class A VCCI V 3 EN 50082 1 AS NZS 3548 89 336 EEC Electromagnetic Compatibility EMC Meets the EMC requirements of EN 50082 1 including IEC...

Page 28: ...Appendix A Specifications A 4 SWPIM E1 Installation Guide ...

Reviews: