background image

1

2

3

SmartStack STS-RPC Redundant

Power Center

SmartStack STS-PSU Redundant 

Power Supply Unit

Introduction

The SmartStack STS-PSU Redundant PSU is an external 
power supply unit for the SmartStack STS16-20RM Token 
Ring Switch, the SmartStack STS16-20R Token Ring 
Workgroup Switch, and the SmartStack STS16-20FRM 
Token Ring Fiber Switch. 

The STS-PSU can be table mounted or mounted in the STS-
RPC chassis unit, and is connected to the STS16-20RM/
STS16-20R/STS16-20FRM switch via a low voltage DC 
cable. The STS-PSU is used in installations where redundancy 
(increased reliability) is required.

The SmartStack STS-RPC Redundant Power Center is a 
chassis unit designed to hold from one to six STS-PSUs. The 
STS-RPC unit can be table mounted or mounted in any 
standard 19" rack.

Figure 1.  STS-RPC Front Panel

Package Contents

Your STS-RPC package contains the following items:

One STS-RPC (with five blind panels)

One STS-PSU (mounted in the STS-RPC chassis)

One DC power cable

One plastic bag containing rubber pads, rack mounting 
nuts and an Allen key

One STS-RPC/STS-PSU Installation Guide (this 
document)

Your STS-PSU package contains the following items:

One STS-PSU Redundant Power Supply Unit

One DC power cable

One STS-RPC/STS-PSU Installation Guide (this 
document)

Installing the STS-RPC Unit

Use the following steps when table-mounting the STS-RPC 
Redundant Power Center:

1. Mount the four self-adhesive pads in the recesses on the 

bottom of the unit.

2. Place the unit on any stable, flat surface. Leave enough 

room around the unit for ventilation and access to cables.

Caution: Place no more than three units (switches) directly on 
top of any other unit. Doing so may cause damage to the lower 
unit.

Use the following steps when rack-mounting the STS-RPC 
Redundant Power Center:

1. Open the cap on the front of each bracket cover. Using the 

Allen key supplied with the unit, remove the retaining 
screws, keeping them for later use. Push the bracket covers 
towards the back of the unit and lift them off.

2. Position the STS-RPC unit in the rack. Slide the unit up 

and down until the bracket holes line up with the holes in 
the rack. Using the screws from the bracket covers and the 
nuts supplied with the unit, attach the unit to the rack. 
Close the bracket cover caps again to conceal the screws.

Note: Mount the STS-RPC unit in the middle of a stack of 
switches so that the DC cable is able to reach all switches.

Installing the STS-PSU Power Supply Unit

The STS-PSU unit can be table mounted or mounted in the 
STS-RPC chassis.

If you are table mounting the STS-PSU unit, simply place the 
unit on any flat, stable surface. Leave enough room around the 
unit for ventilation and access to cables.

If you are mounting the STS-PSU unit in the STS-RPC 
chassis, use the following procedure:

1. Select a location for the STS-PSU unit in the STS-RPC 

chassis. Any vacant slot can be used.

2. Remove the blind panel by loosening the two 

thumbscrews.

3. Slide the STS-PSU unit into the slot and secure the unit 

with the two thumbscrews.

Connectors and LEDs

The STS-PSU connectors and LEDs are listed below:

Cabling and Applying Power to the STS-PSU

Caution: Both the SmartStack STS-PSU unit and the STS16-
20RM/STS16-20R/STS16-20FRM switch must be off before 
connecting or disconnecting the DC power cable.

Connect one end of the DC cable to the DC outlet on the back 
of the STS-PSU unit (either end of the cable can be used). 
Connect the other end of the cable to the redundant power 
supply connector on the back of the switch (you need one STS-
PSU unit per switch).

Figure 2.  SmartStack STS-PSU Back Panel

Name

Description

DC Connector

18-pin connector for the proprietary 
DC cable.

AC Connector

Standard AC power receptacle.

Power LED

The power LED is on when the
STS-PSU is receiving power.

Table 1.  STS-PSU Connectors and LEDs