background image

6. When prompted for a terminal speed, type the line speed (in bits per 

second) of the attached terminal (

1200, 2400

, or 

4800

) and press 

[Enter]

.

7. When asked: 

Are you changing only the Async console or LAN adapter con-

figuration?

, press 

[Y]

.

8. You will be asked: 

How many LAN cards have you installed (0-2)?

Even though you are changing only the async terminal setup, 
you must redo the LAN card setup (if cards are installed), since
changing the terminal setup writes over a file that contains the 
specifications for the terminal and the LAN cards.

If none, press 

[Enter] 

to accept the default of

 0

, then go to step 10. Oth-

erwise, enter the number of LAN cards and go to step 9.

9. You will be asked to specify the type of LAN card 0. (LAN cards are num-

bered 

0

 and 

1

.) Enter the appropriate number from the choices:

3 – SMC EtherCard Plus Elite16
4 – IBM Token Ring Card
5 – SMC Token Ring Card

The IBM card is not currently offered, but is supported by the 
software for some functions. Discuss your configuration 
requirements with Cabletron Systems Technical Support if a 
node contains an IBM card.

If only one LAN card is installed, go to step 10. If two are installed, repeat 
step 9 for the second card, then go to step 10.

10. Remove the diskette, switch the FRX6000 and VGA monitor off, and dis-

connect the monitor from the FRX6000's VGA port.

11. Install the console and cabling as shown in Figure 4 through Figure 6.

12. Set up the terminal as described in the user's manual for that terminal, with 

the terminal should be set to:

Autowrap,

Application Keypad

Application cursor key

No newline

No break

VT100 (ASCII) mode

Tab every 8 columns

8 bits no parity

Installation & Setup Guide

7

VGA Monitor

1. Connect the monitor to the VGA port on the FRX6000 (see Figure 1) and 

plug the keyboard cable into the keyboard connector.

2. Plug the FRX6000 and VGA monitor power cables into the appropriate 

power source, then switch the monitor on.

3. Insert the FRX6000 System Disk into the node's drive A and switch the 

node on.

4. A message concerning LAN card configuration will be displayed. When 

prompted: 

Strike any key when ready

, press 

[Enter]

.

5. When asked:

 Will you be using an Async terminal to configure your 

FRX6000?

, press 

[N]

.

6. When asked: 

Are you changing only the Async console or LAN adapter con-

figuration?

, press 

[Y]

.

7. You will be asked: 

How many LAN cards have you installed (0-2)?

Even though you are changing only the async terminal setup, 
you must redo the LAN card setup (if cards are installed), since
changing the terminal setup writes over a file that contains the 
specifications for the terminal and the LAN cards.

If none, press 

[Enter]

 to accept the default of 

0

, then go to step 9. Oth-

erwise, enter the number of LAN cards and go to step 8.

8. You will be asked to specify the type of LAN card 0. (LAN cards are num-

bered 

0

 and 

1

.) Enter the appropriate number from the choices:

3 – SMC EtherCard Plus Elite16
4 – IBM Token Ring Card
5 – SMC Token Ring Card

The IBM card is not currently offered, but is supported by the 
software for some functions. Discuss your configuration 
requirements with Cabletron Systems Technical Support if a 
node contains an IBM card.

If only one LAN card is installed, go to step 9. If two are installed, repeat 
step 8 for the second card, then go to step 9.

9. Remove the diskette from the drive.

8

FRX6000

Summary of Contents for SPECTRUM FRX6000

Page 1: ...QVWDOODWLRQ 6HWXS XLGH The Complete Networking Solution TM...

Page 2: ...ications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to at his her own expense take the necessary measures to elim...

Page 3: ...6 9d 7 0h front panel is 19w Cm 48 3w 42 9d 17 8h front panel is 48 3w Hardware Requirements Although a keyboard and video device are not necessary for normal operation they are required for initial c...

Page 4: ...h the I O boxes and cables as shown in Figure 3 using the hardware provided Leave a 24 36 inch service loop in each cable between the mounting rails and the rear of the node to allow the unit to be pu...

Page 5: ...e cabling configurations Figure 4 Auxiliary Console Cabling Example 1 Installation Setup Guide 5 Figure 5 Auxiliary Console Cabling Example 2 Figure 6 Auxiliary Console Cabling Example 3 Follow this p...

Page 6: ...ursor key No newline No break VT100 ASCII mode Tab every 8 columns 8 bits no parity Installation Setup Guide 7 VGA Monitor 1 Connect the monitor to the VGA port on the FRX6000 see Figure 1 and plug th...

Page 7: ...include copyright information debug messages and messages tracking the loading of RLPs Watch power up and boot messages carefully some errors will cause a pause but otherwise will not interfere with...

Page 8: ...the Reports Menu or F then C from the Main Menu To display the data from the previous boot up saved in a file called BOOTBAK TXT press D at the Reports Menu or F then D from the Main Menu BOOTRPT TXT...

Page 9: ...Document number 09 41 06 144 02 The Complete Networking Solution TM...

Reviews: