Cabletron Systems SmartSwitch 2200 Instruction Sheet Download Page 4

 

P/N 9032790-01

Page 4 of 4

 

CONNECTING THE DEVICE TO A 48/60 VDC POWER SOURCE

 

To connect the device to a 48/60 Vdc power source, face the rear of the device, then refer to Figure 6 and proceed as 
follows:

 

Figure 6

Connecting 48/60 Vdc Power Source to the Power Supply

 

1. Connect the ground 

 terminal of the dc input power strip to an appropriate earth ground.

2. Refer to Figure 6 for the proper connections to a 48/60 Vdc power source. Then connect the output leads of the 

48/60 Vdc power source being used to the negative (-) and positive (+) terminals on the dc input power strip.

3. Repeat steps 1 and 2 to connect a 48/60 Vdc power source to the other dc input power strip on the device.

4. Restore power from the 48/60 Vdc power sources. If an alarm sounds, refer to the following note.

5. Press the on/off power switch of each power switch to the on position.

6. Follow the instructions provided in your SmartSwitch 2200 user’s guide to install, power-up, and connect the device 

to the network. 

 

GETTING HELP

 

For additional support, contact Cabletron Systems using one of the following methods:

 

 

 1999 by Cabletron Systems, Inc., P.O. Box 5005, Rochester, NH 03866-5005

All Rights Reserved. Printed in the United States of America. 
Order Number: 9032790-01 January 1999

 

Cabletron Systems

 

 is a registered trademark and

 

 SmartSwitch 

 

is a trademark of Cabletron Systems, Inc. 

All other product names mentioned in this document may be trademarks or registered trademarks of their respective companies.
The information in this document is proprietary and is not to be copied in any form, or by any means, without the written consent of Cabletron Systems.

 

To prevent injury or damage to the equipment, remove power from the 48/60 Vdc power sources before 
proceeding with the following steps and 

 

do not

 

 restore the 48/60 Vdc power until instructed to do so.

NOTE

 

If a dc power supply sounds an audible alarm, there is a polarity reversal. Turn off the 48/60 Vdc power 
source to that power supply, then reverse the positive and negative leads to the dc input power strip of that 
power supply. Restore power from the 48/60 Vdc power source. If the alarm sounds again, turn off the 
48/60 Vdc power source and call for technical support. Refer to 

 

Getting Help 

 

for instructions.

 

World Wide Web

http://www.cabletron.com/ 

Phone

(603) 332-9400

Internet mail

[email protected]

FTP

ftp://ftp.ctron.com/

Login 

 

anonymous

 

Password 

 

your email address

 

To send comments or suggestions concerning this document, contact the 
Cabletron Systems Technical Writing Department via the following 
email address:

 

[email protected]

 

Make sure to include the document Part Number in the email message.

2790-01

ON/OFF

DC Input Power Strip

48 or 60 Vdc
Power Source

+

-

Earth
Ground